![Bishamon SPA4000 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/bishamon/spa4000/spa4000_manual_2757115024.webp)
23
11-4. Arms
1. Check that the stopper is effective when fully withdrawing the slide arm, and that the stopper bolts
are not loose.
2. Check that the slide is not inhibited by contaminants, rust, etc.
3. Check the lift arm thickness.
Replace if 20% less than the standard dimensions.
11-5. Base
1. Tighten the anchor bolts with 100N·m torque.
2. Check that there are no abnormalities such as bulges or cracks in the floor around the anchor bolts.
3. Tighten the bolts (M16) that secure the post and base using 250N·m torque.
11-6. Rust
1. Check for rust.
⇒
Remove any rust, and then paint repair coats.
Thoroughly check the posts, carriages, and arms.
Standard
thickness
Limit
thickness
[1] 2-step long arm
A dimensions
6.0mm
4.8mm
[2] 2-step short arm
B dimensions
6.0mm
4.8mm
[2] 2-step short arm
Stopper bolt
[1] 2-step long arm
Stopper bolt
A
B