Air Filter Regulator reduce the air pressure of the air supplied to Air Filter Regulator
gauge shows the air pressure after depressurization.
① Verify that the air pressure supplied to the
Air Filter Regulator is more than 0.5 Mpa
② Loosen the screw on top of the Air Filter
Regulator.
③ Look at and check the air pressure gauge while
turning the pressure adjustment knob to set the
air pressure to 0.5 Mpa.
④ Tighten the screw on the top of Air Filter
Regulator.
① Push up the drain valve at the bottom.
Water sprays out with air.
to appropriate air pressure levels (0.7~1.0MPa), and drain water in the air. Air pressure
Depressurize
Pressurize
Pressure
adjustment knob
Air pressure
gauge
Screw
*
The appropriate value of the pressure of air (primary side pressure) supplied to the filter
regulator is between 0.7 and 1.0 MPa. The filter regulator could be damaged if the
pressure is greater than 1.0 MPa.
* Always make sure that the air pressure gauge is pointing 0.7 MPa before operating lift.
The lift may malfunction if the pressure is under 0.5 MPa. Furthermore, the Selex valve
may be damaged if the pressure is over 0.7 MPa. Always set the pressure to 0.7 MPa.
Caution
Drain valve
Drain water must be drained from the air filter regulator every day.
Accumulation of water can cause malfunction.
Caution