10
there is no data in the memory.
3.3 Weighing Mode
Press repeatly
MODE(ENT)
until display shows the weighing unit set in configuration scale(Fn3).
Press
ZERO(↑)
to reset the scale and put the objects to be weighed on platter.
3.4 Piece Counting Mode
The scale equipped with simple piece counting function, please follow the below procedure to
enable the function and sampling method.
a)
Indicator is on and both Zero indicator and Stable indicator are on.
b)
Press
MODE(ENT)
until display shows PCS as weighing unit on the display.
c)
Press
MR(↓)
and display shows “S: 10”, this means count 10pcs of the same item to put on
platter for sampling the average unit piece weight.
d)
If 10pcs is not the prefer sampling quantity, continue to press
ZERO(↑)
and display will show
“S:20”, “S:50”, “S:100”, “S:200”, “S:500” and “S:1000”. When the ideal quantity is reached,
press
MODE(ENT)
to confirm and put the sample quantity on platter. Do not load the platter
before pressing
MODE(ENT)
key.
e)
Scales will begin the sampling process to calculate the unit piece weight, when the sampling
is done scale will show the sampled quantity on display.
f)
Remove the load and put new batch, display will show the batch quantity.
g)
If display shows a value while platter is empty, press
ZERO(↑)
to zero off the weight.
h)
If a new sampling is needed, press and hold
MR(↓)
to start new sampling by following step c
to d.
NOTE:
1.
If scale detects the total weight of samples on the platter are smaller than 20d, the PCS sign will
start flashing as warning. Press
ZERO(↑)
key to change the sampling quantity setting or add more
samples until the signal is off.
2.
If scale detects the unit piece weight of the sample is smaller than minimum unit weight, the
PCS sign will start flashing as warning (unit piece weight must not small than 0.5d). It is
recommended using smaller capacity scale for this sampling.
3.
When PCS sign flashes, sampling process can still in process but might result errors.
Содержание HSW