BIS BISTRADCE Скачать руководство пользователя страница 1

EPA  Wood-Burning Fireplace

P/N  506128-19  REV. J  05/2013 

BISTRADCE

MODEL

BIS

®

 TRADITION CE

INSTALLATION AND 

OPERATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

FOR FUTURE REFERENCE 

Listed to standards:
ULC-S610 and UL-127
Report No. 307-4084
EPA Cert. No. 537

     

WARNING

 

Hot! Do not touch!  The glass and 

surfaces of this appliance will be hot 

during operation and will retain heat 

for a while after shutting off the appli-

ance.  Severe burns may result. 

• 

 

Carefully supervise children in the 

same room as appliance.

•  If small children are present in the home, it is 

recommended that this appliance be fitted with 

an adjustable safety gate or barrier screen.

       WARNING

 

The fireplace cannot be operated without a door 

or firescreen.  Consult your dealer to select the 

correct replacement door or firescreen.

 

The fireplace is equipped with a blower, electri-

cal connection must be made prior to fireplace 

installation

 

Important! To assure proper alignment of glass 

doors: Install this fireplace in a square and 

plumb condition, using shims as necessary at 

sides and/or bottom.

 

Install the fireplace only as described in these 

instructions.

PIBISTRADCE  REV. 9  05/2013

This installation manual will enable you to obtain a safe, efficient 
and dependable installation of your fireplace system. Please read 
and understand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any cir-
cumstances.  Any modification or alteration of the fireplace system, 
including but not limited to the fireplace, chimney components and 
accessories, may void the warranty, listings and approvals of this system 
and could result in an unsafe and potentially dangerous installation.

IHP wood-burning fireplaces are designed for use as a supplemental 
heater.   They are not intended for continuous use as a primary heat 
source.

Fireplace, also for use in mobile or 

manufactured homes with solid fuel only.

5/1

0/2

01

3

An French manual is available upon request. Order P/N 506128-20.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro 
de la pièce 506128-20.

Содержание BISTRADCE

Страница 1: ...t of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions PIBISTRADCE REV 9 05 2013 This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your ins...

Страница 2: ...nsure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operation nor are we respon sible for inadequate system draft caused by mechanical systems general construction conditions inadequate chimney heights adverse wind conditions and or unusual environmental facto...

Страница 3: ...eparately See Page 20 Front Facade kit Required Order Separately See Page 20 UZY5 blower included in the fireplace VRUW Blower Speed Control included Outside air kit Included w Fireplace OPTIONAL EQUIPMENT Additional Equipment optional Forced Air Kit u AC Chimney Adaptor required if using AC Chimney Congratulations When you purchased your new fireplace you joined the ranks of thousands of individu...

Страница 4: ...ed during 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium setting You know you have reached the desired temperature when closing the primary air control you can see a flame at the top of the firebox The benefit of this techniquewillbecleanerglass le...

Страница 5: ...oduces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney shall be inspected at least twice a year during the heating season to determine when a creosote...

Страница 6: ... to perform a test of the integrity of the door seal Close the door on the paper in at least eight points It is normal to feel only a slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace Figure 5 Door Installation WARNING Use only a IHP glass doors specifically designed ...

Страница 7: ...t cover the entire width of the fireplace The combustible floor in front of the fireplace mustbecoveredwithanon combustiblemate rial tile marble stone etc See Figures 7B Cold climate INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulation house design how the appliance is operated etc If this firep...

Страница 8: ...ustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calcula tions will need to be made The fireplace must not be...

Страница 9: ...utside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 X 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest of the building below the attic SEE NOTE Mantel and Facing Th...

Страница 10: ...acer Figure 12 Fireplace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied with the unit located on the bottom right corner of the fireplace If you wish to adjust the blower speed the var...

Страница 11: ... use a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplatesclosingupthe8 dia holes on top of the fireplace Then cut the insula tion in order to obtain two 8 dia openings Fix the adaptors on the fireplace openings by turning clockwise Figure 15 2 Maintain...

Страница 12: ... When offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE 2 clearancetocombustiblesaroundchimneycomponentsrequired NOTE Blown or fill type insulation materials must not be in contact...

Страница 13: ...oofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt supplied Finally seal the joint between the stormcollarandthechimney usingsilicone caulking 7 Install the chimney cap Once the chimney cap is in place the roof flashing can be wash...

Страница 14: ...4 Use a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop See Figure 22a 6 A support ST or SO must be used on the first 15 section 5 m 7 Continue with the regular installation AC Chimney 1 Install the first elbow Turn it in the requir...

Страница 15: ... 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm 107 3 8 2727 mm 30 A 9 3 8 238 mm 12 3 8 314 mm 21 3 8 543 27 3 8 695 mm 32 5 8 829 mm 35 5 8 905 mm 44 5 8 1134 mm 50 5 8 1286 mm B 25 3 4 654 mm 31 787 mm 46 1 2 1181 mm 57 1448 mm 66 1676 mm...

Страница 16: ...stible wall with the chimney at a 30º or 45º angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45º angle for Canada only RSMI45 In cold climate locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 Canada Only Chi...

Страница 17: ...oxandglassaremaintained at hot temperatures see Refueling For Best Performance To clean the glass there are a numberofspeciallydesignedcleaners YourIHP dealercanrecommendasuitablecleanerwhich is available in your area Regular household glass cleaners will not clean creosote Do not use abrasives such as steel pads steel wool or oven cleaner as they will scratch the glass DO NOT USE CHEMICAL GLASS C...

Страница 18: ...ons provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNEY CHASE AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part...

Страница 19: ...onry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30º 3 Increase the size of the hole until a 30º Tubinox liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30º liner elbow and connect it to the liner 6 Add a small liner section to the liner elbow which will allo...

Страница 20: ... 2 grill supports and 2 black grills H8947 Gravity Kit Accessories Elbow 90º 8 dia 7B26ZE90 H8948 Elbow 45º 8 dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Rigid fir...

Страница 21: ...2271 Cast iron Log Retainer Supports Grate 2 PR SR2324 Log retainer bar PR SR2620 Door rod and lock PR SR2118 Steel door glass gasket PR SR1685D Cast iron door glass gasket PR SR1823H Steel and cast Iron door gasket PR SR1823G Touch up Paint Aerosol Black Metallic SBMB6309 H8159 Touch up Paint Charcoal for hammered steel facade PR P6201 Coupler Outside Air connects UZI to fireplace UZIAD Coupler f...

Страница 22: ...s Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6L12 18 length 6 Dia 6L18 6L18 24 length 6 Dia 6L24 6L24 36 length 6 Dia 6L36 6L36 48 length 6 Dia 6L48 6L48 Adjustable Length 12 6 Dia 6LA 6LA 15º elbow 6 Dia 6E15 6E15 30º elbow 6 Dia 6E30 6E30 Rain Te...

Страница 23: ... Description Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Length 6 Dia 6LL36 6LL36 48 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6 Dia 6LT 6LT Tee Cap 6 Dia 6TCS 6TCS Twist Lock Tee Cap 6 Dia 6LTC 6LTC Elbow 30º 6 Dia 6LE30 6LE30 Elbow 45º 6 Dia 6LE45 6LE45 Elbow 90º 6 Dia 6LE90 6LE90 Rain Termination Cap reg...

Страница 24: ...ncerns For the number of your nearest IHP dealer please call 1 800 655 2008 Replacement parts See Page 21 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The mo...

Отзывы: