Measure Match Mode
18
6.
Connect the SiteHawk to the device under test.
7.
Wait 10 Seconds for the sweep to update.
Interpreting the Measurement
The graph below shows a typical Match Measurement for an antenna system.
Figure
9
Interpreting Match Measurement
The graph contains the following elements:
Vertical grid scale (y axis) displays dB and ratio data values.
Horizontal grid scale (x axis) displays frequency, time or distance data
values.
The measured value of the Markers (1 and 2 in this example).
Trace number (Tr1) and color is used identify the trace.
When scanning duration is more than 1 second, a current position
indicator will appear.
Cable Loss Measurement
Ensure that the cable being tested is unterminated (not connected to anything
at the far end).
Note:
Ensure the cable is disconnected from any RF power source.
Note:
Ensure the frequency band of the system is known.