Initialisation (see operating instructions, chapter 4)

Reglobeam remote control

Bircher Reglomat AG,

headquarters Switzerland Tel. +41 (0)52 687 11 11, Germany Tel. +49 (0)7031 70 60 0

Electrical connections

Settings with Reglobeam

Installation and adjustment

1. Fit housing (see operating instructions, chapter 2).
2. Click US beams into aluminium profiles.
3. Check whether the US beams are clicked in correctly and therefore secured

well in the profile!

3. . Position US beams and set inclination angle

The left and right bearing clamps must be at the same angle

(see operating instructions, chapter 4.3).

4. If several sensors are used, connect these with the ribbon cable

(see operating instructions, chapter 4.1).

5. Click cover onto profile (working from front to back) and ensure that the

US beam's inclination angle doesn't change!

1
2
3
4
5
6

common
nc*
no*
Test input

Diagram for door side A or B:

Diagram for door controller with Y adapter:

General:

If

G

flashes, a connection to the sensor could not be established.

Disconnect the power supply of the UniScan briefly or press the two
buttons on the sensor for 1 second.

Direct the Reglobeam remote control more exactly and directly at the
sensor.

30 minutes after the last setting was undertaken on the sensor,
configuration mode is automatically exited.

a) Initialisation is undertaken by pressing the keys

F + 3 + 6

on the Reglobeam remote control or by pressing the green key for 5 seconds!

b) If both LEDs (red/green) flash, this indicates that the function has been triggered. The detection area must be exited within 6 seconds.
c) If the red LED then flashes, this indicates that initialisation is under way. The detection area must not be entered during this time!
d) Initialisation is complete when both LEDs go out.

Key

Function

Key

Brief description of function

A

Test input

1
2
3
4

5

«High» active, pull up
«High» active, pull down
«Low» active, pull up
«Low» active, pull down

Test input deactivated*

B

Switch light points on and off
Note: Once one or more beams have been
switched on and off, re-initialise using F+3+6

1+ 1 oder 2
2+ 1 oder 2
3+ 1 oder 2
4+ 1 oder 2
5+ 1 oder 2
6+ 1 oder 2
7+ 1 oder 2
8+ 1 oder 2

9

Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
Beam 1 selected, activate with key 1, deactivate with key 2
All beams on

Factory setting: Energy-saving beam pattern 1-3-5-7-8 on

C

Output signal

1

2

6

The relay picks up when a detection takes place (active)

The relay drops out when a detection takes place (passive)

Restart

D

Sensitivity

1
2
3
4
5
6
7

Object height > 10 cm
Object height > 20 cm if sensor mounting height is up to 3 m

Object height > 20 cm if sensor mounting height is up to 2.7 m

Object height > 30 cm**
Object height > 50 cm**
Object height > 70 cm**
Object height > 100 cm*

Factory setting,

*Setting not TÜV-compliant regarding type approval, **above a mounting height of 2.7 m, setting not TÜV-compliant regarding type approval

This information sheet does not replace the
original operating instructions!
Read the operating instructions before
commissioning the device!

Note:
Single operation is only possible
with an alternating current supply!

Page 1 of 2

Short guide

UniScan / US beam

1 test input
2 no
3 nc
4 common
5

⁄~

6 +/~
7 common
8 nc
9 no
10 test input

6
5
4
3
2
1

1
2
3
4
5
6

common

common

nc

nc

no

no

test input

test input

To sensor master
on the front of the
door (hinge side of
the door)

To sensor master
on the back of the
door(non-hinge side
of the door)

To door controller