Series Connection Diagram
Prime
Tec
/
Prime
Scan
(independent of operator)
1
Operator designation
2
Important safety instructions
3
Settings
4
AIR series connection
ENGLISH
00004632A
09/15
Standard connection diagram (independent of operator) for PrimeTec/PrimeScan series circuit.
Please see the respective connection diagram for operator-specific connection.
– Refer to the original operating instructions regarding detector installation and start-up.
– Connect the exterior and interior detectors using the interior and exterior connections of the controller provided for this purpose.
– Test the function and the correct settings of the detectors in connection with the door.
The AIR output logic of the Slave must be adjusted in accordance with that of the Master!
The
Master
is a detector at which the test input is connected to the controller.
Slave is a detector that receives the test signal from a preceding detector.
Depending on the operator, up to 4 detectors can be connected in series.
OPERATION OF
THE BUTTONS
1
DESCRIPTION
Function
Value
LCD
RegloBeam2:
Mode
AIR output
contact
logic
3
1 – 4
2
E
+
(with PrimeTec A
only)
= active (NO)
No detection
Contact open
* = passive (NC)
No detection
Contact closed
Series connection
Settings
Master
➔
Slave
Master
➔
Slave
Note:
Neighbouring detectors require different frequencies in order to prevent IR interferences with overlapping fields.
For power supply and radar output connection, see original operating instructions.
As a basic rule, both connection options can always be applied.
We recommend that the connection be made in accordance with the type of light barrier, as the GND or +VDC supply voltage can be linked together
thereby.
2 Detectors
The number of required detectors depends on the application.
* Factory setting
Bircher Reglomat AG
, Wiesengasse 20, CH-8222 Beringen, www.bircher-reglomat.com, [email protected]
1 / 2
Controller
–
+
–
+
–
+
Test
11,5 – 32 VDC
AIR IN
Controller
–
+
–
+
–
+
Test
11,5 – 32 VDC
AIR IN
grey
grey
pink
pink
pink
blue
grey
red
blue
blue
red
Option 1: NPN light barrier input
Option 2: PNP light barrier input
red
blue
pink
grey
Master
Slave
Master
Slave
red