Series Connection Diagram

Prime

Tec 

/

 

Prime

Scan

 

(independent of operator)

1

Operator designation 

2

Important safety instructions

3

Settings 

4

AIR series connection 

ENGLISH

00004632A

09/15

Standard connection diagram (independent of operator) for PrimeTec/PrimeScan series circuit.
Please see the respective connection diagram for operator-specific connection.

–  Refer to the original operating instructions regarding detector installation and start-up.
–  Connect the exterior and interior detectors using the interior and exterior connections of the controller provided for this purpose.
–  Test the function and the correct settings of the detectors in connection with the door.

The AIR output logic of the Slave must be adjusted in accordance with that of the Master!

The 

Master

 is a detector at which the test input is connected to the controller.

Slave is a detector that receives the test signal from a preceding detector.

Depending on the operator, up to 4 detectors can be connected in series.

OPERATION OF  

THE BUTTONS

DESCRIPTION

Function 

Value 

LCD

RegloBeam2: 

Mode 

AIR output

contact

logic

   

3

1 – 4

2

E

 

+

 

(with PrimeTec A 

only)

 

= active (NO)

 

    No detection

 

    Contact open

*  = passive (NC)

 

  No detection

 

  Contact closed

Series connection

Settings

Master 

 

➔ 

Slave 

Master 

 

➔ 

Slave 

Note: 

Neighbouring detectors require different frequencies in order to prevent IR interferences with overlapping fields.

For power supply and radar output connection, see original operating instructions.

As a basic rule, both connection options can always be applied.
We recommend that the connection be made in accordance with the type of light barrier, as the GND or +VDC supply voltage can be linked together 
thereby.

2 Detectors 

The number of required detectors depends on the application.

* Factory setting

Bircher Reglomat AG

, Wiesengasse 20, CH-8222 Beringen, www.bircher-reglomat.com, [email protected] 

 

1 / 2

Controller

+

+

+

Test

11,5 – 32 VDC

AIR IN

Controller

+

+

+

Test

11,5 – 32 VDC

AIR IN

grey

grey

pink

pink

pink

blue

grey

red

blue

blue

red

Option 1: NPN light barrier input 

Option 2: PNP light barrier input

red

blue

pink

grey

 Master 

 

Slave 

 Master 

 

Slave 