Observe the national and international regulations on door safety.
Only trained, qualified personnel may mount and start up the detector.
The unit may only be opened and repaired by Bircher Reglomat.
The unit may only be operated from a safety extra-low voltage (SELV) system with safe electrical separation.
Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system.
The installer is responsible for carrying out a risk assessment and installing the detector and the door system correctly.
Avoid touching any electronic components.
The door drive and transom profile must be earthed correctly.
Start-up
2
Montage
Translation of the original instructions
Recommended start-up sequence: I. Mounting
II. Connection
M
o
u
n
ti
n
g
I
General
Safety instructions
1
Pleas
e kee
p for
furthe
r use
!
Quality
international
level
EN ISO
9001
Hood,
Light window de-
tector indication,
no function,
Cable bushing,
Mounting holes,
Detector electronic,
Microwave module,
LED microw.: green
PrimeMotion B
1.
Remove cover hood
2.
Lay and connect cable
3.
Mount detector
Radarfeld
Microwave motion detector for opening
automatically controlled doors
1.
Position drill template
2.
Drill the holes, remove drill template
3.
Lay cable and mount detector
Year of construction 2010
E
N
G
LI
S
H
Mounting of the detector
II
Electrical connections
C
o
n
n
e
c
ti
n
g
3
PrimeMotion B ES
Controller
1 brown
2 white
3 green
4 yellow
Cable
brown
white
green
yellow
Power Supply
3 m
Relay
–
+
11.5 - 36 VDC
12 - 28 VAC
Microwave
1
2
3
4
4 3 2 1
+
Mechanical fine tuning
4
–
–
+
+
Manual settings of the
inclination
0° ... +45° in 5° steps
Manual settings of the
pivoting
– 20° ... +20° in 5° steps
–
–
+
+
1m
2m
0m
0m
1m
2m
3m
4m
Wide radar field
turn 90°
Narrow radar field
min. = 0.16 x 0.8, max. = 2 x 4 m (WxD)
min. = 0.5 x 0.25, max. = 4 x 2 m (WxD)
+
1m
2m
0m
0m
1m
2m
3m
4m
–
–
Inclination angle: 35°
Inclination angle: 35°
2.
2
m
2.
2
m
–
90°