Supplying oxygen to ozone generators with oxygen generators.
●
While using an oxygen generator to supply oxygen to the ozone generator, lead oxygen from oxygen
generator to oxygen inlet 9 (fig.4) Leave air outlet 7 of ozone generator in this manual (fig.4)
un-connected, and air pump switch 2 (fig.4) off.
●
While using oxygen generators to supply oxygen to ozone generators, SOZ-YOB-G integrated
oxygen ozone generators from our company can be a good substitution.
Advantage and shortcoming of using an oxygen generator: convenient operation, but the cost is
higher than equipping silica gel drying tank and inner heating-drying tank.
To supply oxygen to ozone generator with oxygen cylinder
●
While using an oxygen cylinder to supply oxygen to the ozone generator, connect oxygen from
oxygen cylinder to oxygen inlet 9 (fig.4). Leave air outlet 7 of ozone generator, in this manual (fig.4)
unconnected and air pump switch 2 (fig.4) off.
●
While using oxygen cylinders to supply oxygen to ozone generators, SOZ-YOB-G integrated oxygen
ozone generators from our company can be a good substitution.
Advantage and shortcoming of using oxygen cylinders: convenient operation, but have to often buy
oxygen and replace oxygen cylinders.
FAULT INSPECTION AND ANALYSIS
Maintenance staff must be qualified electricians; maintenance and repair must be conducted when the
equipment is off power and air pressure is completely released; ensure safe maintenance.
After the following inspections are completed, if there are still problems unsolved or cases related with
maintenance, please contact the local distributor or post sale service department of our.
Power connection failure
●
Check whether the power plug has been properly inserted; voltage is about 220V/230V (or 110V if
specified in purchase order from factory).
●
Check tube fuse if it is burned out, replace one with the same type and check whether input voltage
is normal.
●
Check whether there is input and output voltage in the 110V/220V transformer. If there is 110V input
but not 220V output, it indicates that the transformer is damaged. (this inspection is only for 110V
products).
No output from ozone outlet
●
Check out whether the air pump switch is open; whether there is input to oxygen inlet, whether the
air pump is switched or damaged.
●
If there is oxygen input, examine whether flow rate is normal, whether the joints on the pipeline are
leaking or fallen off, or the pipeline is twisted.
●
No ozone, no working electric current, ozone light not bright (with gas output, but not ozone)
●
Check whether ozone volume regulating button is adjusted too low
●
Whether or not the main board indicating light is on
●
Off: check whether the fuse tube of the main board is burned out , if so, replace one with the same
type (3a) and check whether input voltage is normal; if it's burned out once more the main board is
damaged. Check whether there is AC220V input on the 12# socket of the main board; whether the
temperature controller of the ozone generator tube and ammeter are normal.
On: Check whether there is AC160V input on the 44# socket of the main board; if not, the main
board is damaged