CONTROL PANEL AND INTERFACE
4.1 CONTROL PANEL DESCRIPTION
●
Ozone regulating knob
○
Amount of ozone can be adjusted by adjusting the working current and the adjustable range
is from 0% to 100%
●
Power indicator
○
Light up when equipment work normally
●
Operation indicator
○
Light up when equipment work normally and extinguished when equipment is abnormal
●
Fault indicator
○
Extinguished when equipment is normal and light up when a fault is detected;
●
Power switch
○
Ozone generator on/off control. 30 second delay and then start making ozone.
●
Ammeter
○
Ozone generation working current. The working current cannot exceed the current in the
specification.
●
Equipment overcurrent protection
○
This feature is reserved
●
IGBT overcurrent protection
○
This feature is reserved
●
High voltage transformer overheat protection
○
When the indicator lights up, check whether high voltage transformer cooling fan is working,
the ambient temperature is too high and the equipment cooling fan dust filter is blocked
●
Back flow water protection:
○
The indicator lights up when back flow water is detected. Checking non-returning valve and
backflow water prevention devices (if applicable) is normal.
●
Cooling water overheat protection
○
The indicator lights up when the discharge tube temperature is too high. Check whether the
cooling water valve is open and the flow rate is too low ;
●
High pressure protection
○
This feature is reserved
●
Low pressure protection
○
This feature is reserved