background image

CONTROL PANEL AND INTERFACE

4.1 CONTROL PANEL DESCRIPTION

Ozone regulating knob

Amount of ozone can be adjusted by adjusting the working current and the adjustable range
is from 0% to 100%

Power indicator

Light up when equipment work normally

Operation indicator

Light up when equipment work normally and extinguished when equipment is abnormal

Fault indicator

Extinguished when equipment is normal and light up when a fault is detected;

Power switch

Ozone generator on/off control.  30 second delay and then start making ozone.

Ammeter

Ozone generation working current. The working current cannot exceed the current in the
specification.

Equipment overcurrent protection

This feature is reserved

IGBT overcurrent protection

This feature is reserved

High voltage transformer overheat protection

When the indicator lights up, check whether high voltage transformer cooling fan is working,
the ambient temperature is too high and the equipment cooling fan dust filter is blocked

Back flow water protection:

The indicator lights up when back flow water is detected. Checking non-returning valve and

backflow water prevention devices (if applicable) is normal.

Cooling water overheat protection

The indicator lights up when the discharge tube temperature is too high. Check whether the

cooling water valve is open and the flow rate is too low ;

High pressure protection

This feature is reserved

Low pressure protection

This feature is reserved

6

Содержание AQUAZONE 200G

Страница 1: ...d ventilation To prevent backflow water gas liquid mixing connections should be installed strictly according to this guide At least allow 5 seconds to turn on and off the ozone generator Please keep t...

Страница 2: ...4 1 CONTROL PANEL DESCRIPTION 6 300G INTERFACE 8 200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9 4 20MA ANALOG SIGNAL RECEIVING PORT 10 INSTALLATION AND MAINTENANCE 11 INSTALLATION PLACE REQUI...

Страница 3: ...ill lead to equipment oxidised and is harmful to staff around Staff is prohibited to enter the space when the machine is being used for space sterilisation In other words business time and sterilisati...

Страница 4: ...s to be in good ventilation and install an exhaust fan if necessary The ambient humidity must not be higher than 90 otherwise there will be water drops inside the equipment causing electricity leakage...

Страница 5: ...ated power supply unit which has comprehensive control and protection The modular design has also made it quite simple for maintenance Anti moisture HV transformer design The HV transformer is sealed...

Страница 6: ...design 3 5A each set Two sets modular design Power 2 5 3 5 4 8 7 0 Working pressure 0 2bar Cooling water flow 25 6LPM 10LPM 12LPM 20LPM Ambient temperature 40 Ambient humidity 70 Cooling water input...

Страница 7: ...the specification Equipment overcurrent protection This feature is reserved IGBT overcurrent protection This feature is reserved High voltage transformer overheat protection When the indicator lights...

Страница 8: ...7...

Страница 9: ...water outlet Outlet water temperature should be lower than body temperature feeling cool otherwise a higher flow is required Ozone outlet A non returning check valve and backflow water prevention dev...

Страница 10: ...200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9...

Страница 11: ...4 20MA ANALOG SIGNAL RECEIVING PORT 10...

Страница 12: ...xygen Cooling water pipe DN20 PVC is suggested The inner diameter needs to be over 10mm Ozone output pipe 304 316 stainless steel pipe or PTFE pipe is suggested The inner diameter needs to be over 15m...

Страница 13: ...mable material accessories and the L series products from Biozone are warranted for one year from the date of purchasing The following occasions are excluded from the warranty and Biozone may charge f...

Страница 14: ...net Clean replace Cycling clean Dry moisture on high voltage parts Clean Maintain during humid season Inner side of internal and external electrode Clean Regular clean when used in beverage and food...

Страница 15: ...se cooling water flow 5 Disconnect the 4 20mA signal and check 6 Replace potentiometer 7 Replace the digital power supply unit 4 Low ozone output low current over 0 5A but lower than rating current Ad...

Страница 16: ...SU output cables Check HV transformer and the connections Clean the cooling channels replace cooling fan Lower ambient temperature E11 PSU IGBT over heated Cooling fan channel blocked or cooling fan i...

Страница 17: ...CONTACT US 16...

Отзывы: