PSU ERROR CODE AND SOLUTION

Error
code

Description

Possible cause

Solution

E001

PSU

Over

current

Input voltage too low

Check the mains voltage, and make sure
correct and firm connection

E002

Working current changes too fast

Slower regulation control

E003

Rapid changes on the load or problem with
the loads

Check ozone cell and HV transformer

E004

PSU

over

voltage

Input voltage abnormal

Check the mains voltage, and make sure
correct and firm connection

E005

Working current changes too fast

Slower regulation control

E006

PSU output voltage increase too fast

Change settings on the parameters

E007

Rapid changes or problem with the loads

Check ozone cell and HV transformer

E008

Phase loss

PSU input R, S, T phase loss

Check the mains voltage, and make sure
correct and firm connection

E10

IGBT
protection

PSU Output short circuit
Load short circuit or abnormal
Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high

Check PSU output cables
Check HV transformer and the connections
Clean the cooling channels, replace cooling
fan
Lower ambient temperature

E11

PSU

IGBT

over heated

Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high

Clean the cooling channels, replace cooling
fan
Lower ambient temperature

E12

rectifier
modules over
heated

Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high

Clean the cooling channels, replace cooling
fan
Lower ambient temperature

E13

PSU overload

PSU input voltage too low
PSU Over current

Check the mains voltage, and make sure
correct and firm connection
Decrease the current by setting to lower
ozone

Note

If the problem still exists after the above inspection, please contact our company or local distributor.

All maintenance/replacement can only be conducted when the power is off and pressure released,
ensuring the safety of the operation personnel.

When servicing a SOZ series ozone generator with multi-set individual control, make it clear of the
component in each set (AB set: breaker, contactor, relay, digital power supply unit, transformer,
ozone cell, cooling pipe, control panel).

15

Содержание AQUAZONE 200G

Страница 1: ...d ventilation To prevent backflow water gas liquid mixing connections should be installed strictly according to this guide At least allow 5 seconds to turn on and off the ozone generator Please keep t...

Страница 2: ...4 1 CONTROL PANEL DESCRIPTION 6 300G INTERFACE 8 200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9 4 20MA ANALOG SIGNAL RECEIVING PORT 10 INSTALLATION AND MAINTENANCE 11 INSTALLATION PLACE REQUI...

Страница 3: ...ill lead to equipment oxidised and is harmful to staff around Staff is prohibited to enter the space when the machine is being used for space sterilisation In other words business time and sterilisati...

Страница 4: ...s to be in good ventilation and install an exhaust fan if necessary The ambient humidity must not be higher than 90 otherwise there will be water drops inside the equipment causing electricity leakage...

Страница 5: ...ated power supply unit which has comprehensive control and protection The modular design has also made it quite simple for maintenance Anti moisture HV transformer design The HV transformer is sealed...

Страница 6: ...design 3 5A each set Two sets modular design Power 2 5 3 5 4 8 7 0 Working pressure 0 2bar Cooling water flow 25 6LPM 10LPM 12LPM 20LPM Ambient temperature 40 Ambient humidity 70 Cooling water input...

Страница 7: ...the specification Equipment overcurrent protection This feature is reserved IGBT overcurrent protection This feature is reserved High voltage transformer overheat protection When the indicator lights...

Страница 8: ...7...

Страница 9: ...water outlet Outlet water temperature should be lower than body temperature feeling cool otherwise a higher flow is required Ozone outlet A non returning check valve and backflow water prevention dev...

Страница 10: ...200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9...

Страница 11: ...4 20MA ANALOG SIGNAL RECEIVING PORT 10...

Страница 12: ...xygen Cooling water pipe DN20 PVC is suggested The inner diameter needs to be over 10mm Ozone output pipe 304 316 stainless steel pipe or PTFE pipe is suggested The inner diameter needs to be over 15m...

Страница 13: ...mable material accessories and the L series products from Biozone are warranted for one year from the date of purchasing The following occasions are excluded from the warranty and Biozone may charge f...

Страница 14: ...net Clean replace Cycling clean Dry moisture on high voltage parts Clean Maintain during humid season Inner side of internal and external electrode Clean Regular clean when used in beverage and food...

Страница 15: ...se cooling water flow 5 Disconnect the 4 20mA signal and check 6 Replace potentiometer 7 Replace the digital power supply unit 4 Low ozone output low current over 0 5A but lower than rating current Ad...

Страница 16: ...SU output cables Check HV transformer and the connections Clean the cooling channels replace cooling fan Lower ambient temperature E11 PSU IGBT over heated Cooling fan channel blocked or cooling fan i...

Страница 17: ...CONTACT US 16...

Отзывы: