PSU ERROR CODE AND SOLUTION
Error
code
Description
Possible cause
Solution
E001
PSU
Over
current
Input voltage too low
Check the mains voltage, and make sure
correct and firm connection
E002
Working current changes too fast
Slower regulation control
E003
Rapid changes on the load or problem with
the loads
Check ozone cell and HV transformer
E004
PSU
over
voltage
Input voltage abnormal
Check the mains voltage, and make sure
correct and firm connection
E005
Working current changes too fast
Slower regulation control
E006
PSU output voltage increase too fast
Change settings on the parameters
E007
Rapid changes or problem with the loads
Check ozone cell and HV transformer
E008
Phase loss
PSU input R, S, T phase loss
Check the mains voltage, and make sure
correct and firm connection
E10
IGBT
protection
PSU Output short circuit
Load short circuit or abnormal
Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high
Check PSU output cables
Check HV transformer and the connections
Clean the cooling channels, replace cooling
fan
Lower ambient temperature
E11
PSU
IGBT
over heated
Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high
Clean the cooling channels, replace cooling
fan
Lower ambient temperature
E12
rectifier
modules over
heated
Cooling fan channel blocked or cooling fan
issue
Ambient temperature too high
Clean the cooling channels, replace cooling
fan
Lower ambient temperature
E13
PSU overload
PSU input voltage too low
PSU Over current
Check the mains voltage, and make sure
correct and firm connection
Decrease the current by setting to lower
ozone
Note
●
If the problem still exists after the above inspection, please contact our company or local distributor.
●
All maintenance/replacement can only be conducted when the power is off and pressure released,
ensuring the safety of the operation personnel.
●
When servicing a SOZ series ozone generator with multi-set individual control, make it clear of the
component in each set (AB set: breaker, contactor, relay, digital power supply unit, transformer,
ozone cell, cooling pipe, control panel).
15
Содержание AQUAZONE 200G
Страница 8: ...7...
Страница 10: ...200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9...
Страница 11: ...4 20MA ANALOG SIGNAL RECEIVING PORT 10...
Страница 17: ...CONTACT US 16...