background image

Personal Health Monitoring Services

SM

V I TA L   S I G N S   T R A N S M I T T E R

•   M O D E L : V S T

3

T M

Instruction Manual

Содержание VITAL SIGNS TRANSMITTER VST 3

Страница 1: ...Personal Health Monitoring ServicesSM V I TA L S I G N S T R A N S M I T T E R M O D E L V S T 3 T M Instruction Manual...

Страница 2: ...ntervention 6 Event Button Intervention 6 Immediate Voice Response Intervention 6 Notifications 7 When to Wear Your Vital Signs Transmitter 8 Using the Vital Signs Transmitter for the First Time 9 Get...

Страница 3: ...gns transmitter and may then communicate directly with you and take whatever action is deemed most appropriate at that time If for any reason you are unable to respond Emergency Medical Service EMS pe...

Страница 4: ...he vital signs transmitter is intended for use by only the registered user and should NOT be shared with others DO NOT use the vital signs transmitter in combination with an external cardiac defibrill...

Страница 5: ...iogram ECG including heart rate and body temperature The built in cellular data modem and phone provide both data and voice communications between you and Biowatch Medical s Clinical Monitoring Center...

Страница 6: ...termines that it is necessary to contact you due to an abnormal ECG or other physiological abnormality they will do so by placing a call to the vital signs transmitter When an incoming call is receive...

Страница 7: ...r other medical symptoms To send an alert depress and release the Event Button Once the Event Button has been fully depressed the vital signs transmitter will vibrate to notify you that your medical d...

Страница 8: ...nter Vital signs transmitter has become too loose for normal operation To delay the automatic playing of a message following the vibration depress the Event Button immediately following the notificati...

Страница 9: ...n under which normal perspiration occurs without adversely affecting the transmitter Please see the Technical Specifications section for acceptable operating conditions When NOT to Wear The vital sign...

Страница 10: ...on setting resetting passwords and setting family and physician access to reports Refer to the section labeled Getting Started for set up instructions 3 Charge the vital signs transmitter The vital si...

Страница 11: ...it our website www biowatchmed com or call our customer service center at 1 877 BIOWATCH 1 877 246 9282 2 Provide account set up information After you have subscribed to Biowatch Medical s Personal He...

Страница 12: ...cedure Information Needed Emergency contact s Name relationship to you phone numbers Physician contact s Name type of physician phone numbers Activity Reporting Name relationship to you level of acces...

Страница 13: ...jack on the bottom edge of the vital signs transmitter 4 The LED indicator located on the bottom right hand side of the front label will light with a yellow indicator while the battery is being charge...

Страница 14: ...provide a notification vibration After a five second delay a final message will be played stating that the vital signs transmitter has insufficient battery level to maintain normal function and is tu...

Страница 15: ...other AC adapters are used For replacement AC Adapters and other purchasing informa tion contact Biowatch Medical Inc at 1 877 BIOWATCH 1 877 246 9282 or visit our website at www biowatchmed com CAUT...

Страница 16: ...t snugly and comfortably around your chest just below the chest muscles sternum area The vital signs transmitter should fit snugly so that you can only insert a small finger between the belt and your...

Страница 17: ...of the vital signs transmitter should be upright in the middle of the chest so that it can be read by a person standing in front of you 4 Verify that the vital signs transmitter is working properly b...

Страница 18: ...g soap residue thoroughly dry the vital signs transmitter with a soft towel 3 To clean the elastic strap hand wash in warm soapy water lay strap flat and air dry Store the vital signs transmitter when...

Страница 19: ...troubleshoot the transmitter If you are concerned that your vital signs transmitter is not functioning properly please contact our customer service center at 1 877 BIOWATCH 1 877 246 9282 Please see t...

Страница 20: ...ng with proof of purchase a note including purchase date a brief description of the malfunction and your name address and phone number Limitations related to this warranty are as follows Tampering wit...

Страница 21: ...package to the following address Insurance is recommended Biowatch Medical Inc Attention Warranty 1233 Washington Street Suite 400 Columbia SC 29201 FOR CUSTOMER SERVICE CALL TOLL FREE 1 877 BIOWATCH...

Страница 22: ...110 degrees F Usage Humidity 0 90 relative non condensing Water Resistance water resistant NOT waterproof Outer Dimensions 21 75 x 1 6 x 0 5 VST3 14 x 1 x 0 2 expandable to 33 x 1 x 0 1 elastic strap...

Страница 23: ..._______ N OT E S _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________...

Страница 24: ...1 877 BIOWATCH 1 877 246 9282 www biowatchmed com...

Отзывы: