BioSmart PV-WM Скачать руководство пользователя страница 4

 

                            

 

 

PV-WM Installation Guide v1.2|10.2018|en

 

1.

 

Overview 

The BioSmart PV-WM Reader is a wall-mounted device, designed to capture a palm-vein template 
or RFID card code and send it to BioSmart UniPass controller. Reader is not suited for stand-alone 
application.  

 

Specifications 

Scanner type

 

Infrared

 

Scanning range

 

40-60 mm

 

Integrated RFID card reader

 

EM-Marine, HID, Legic, Mifare, 

 

Card scanning range, mm

 

Up to 50 mm

 

Communication interface

 

Ethernet (IEEE 802.3,100BASE-T)

 

Case opening sensor

 

Yes

 

Power supply

 

12VDC±15%, 0,4 A, PoE 
IEEE802.3af class 3

 

Operating temperature

 

 -40 to +50 °C

 

Design

 

Laid-on plastic

 

Installation

 

Wall mount

 

Dimensions (H x W x D)

 

175 х 150 х 140 mm

 

Weight

 

Net: 650 g; gross: 675 g

 

Warranty

 

5 years

 

 

Содержание PV-WM

Страница 1: ...BioSmart PV WM Installation Guide www biosmart tech com...

Страница 2: ...w 3 Specifications 3 Part names and functions 4 Package contents 4 Opening the case 4 Circuit board 5 Circuit board LEDs and jumpers 5 Connector names and description 5 2 Installation 6 Cable types 6...

Страница 3: ...wed properly before putting the unit into operation Do not turn on the power supply until all installation procedures are finished this may lead to injury or equipment damage Do not disconnect or conn...

Страница 4: ...cation Specifications Scanner type Infrared Scanning range 40 60 mm Integrated RFID card reader EM Marine HID Legic Mifare Card scanning range mm Up to 50 mm Communication interface Ethernet IEEE 802...

Страница 5: ...ein identification Mounting holes Suited for fixing screws Cable inputs Detachable panels suited for cable inputs Package contents Item Number pcs BioSmart PV WM Reader 1 Mounting kit four 6 35 dowels...

Страница 6: ...board is powered up VL27 LED Indicates if PoE supply is on IP RST Jumper IP settings reset BOOT Jumper Boot mode Connector names and description Name Description Used for 1 GND Power supply ground Po...

Страница 7: ...interference All cables must only intersect power cables at a right angle All cable extensions must be soldered Carefully check for mechanical damage on the surface of the reader circuit board and cas...

Страница 8: ...ction Use a DC 12 V power supply adaptor with a minimum of 1 000 mA which has obtained the approval of IEC EN 60950 1 See recommended cable type and maximum length of the cable in Cable types table Po...

Страница 9: ...en UniPass connection UniPass Ethernet connection ports are equipped with PoE sources See recommended cable type in Cable types table The order of connections in the cable s modular connector must co...

Страница 10: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com...