Electrooculography (EOG) 

User Manual  

 

 

  

 

 7 of 17 

 

2.

 

Application Notes 

The  biosignalsplux  EOG  is  designed  to  be  used  in,  essentially,  two  configurations  that  may  be 
combined.  Given  its  bipolar  configuration,  the  measured  signals  correspond  to  the  differential 
between two electrodes given the reference electrode. The relative positioning of the two electrodes 
(positive and negative) allows to infer about the eye movements, specifically, vertical  or horizontal 
movements. 
 

2.1.

 

Reference Electrode 

For the positioning of the reference electrode, it is recommended to be placed in an electrically neutral 
spot in the body. For the EOG, it is common to place it as in Figure 4. 

 

Figure 4 - Placement of the reference electrode. 

 
To measure vertical eye movements, the electrodes should be positioned as illustrated in Figure 5. This 
positioning allows the measurement of the difference of the potential between the above position and 
under position of the eye, thus being indicated to measure the movements in that axis. 

Содержание 820201232

Страница 1: ...biosignal acquisition tool kit for advanced research applications Electrooculography EOG Sensor User Manual...

Страница 2: ...d of the possibility of such damages ATTENTION Please read this datasheet before using your biosignalsplux sensor The information contained in this document has been carefully checked and were made ev...

Страница 3: ...Using the Electrooculography EOG Sensor with biosignalsplux OpenSignals 9 3 1 Connecting the sensor to biosignalsplux Systems 9 3 1 1 biosignalsplux 4 Channel Hubs 9 3 1 2 biosignalsplux 8 Channel Hu...

Страница 4: ...sulting signal is the amplified difference between these two leads eliminating the common unwanted signals Its convenient form factor enables a discrete application in the typical EOG electrode placem...

Страница 5: ...ychophysiology Biomedical device prototyping Biomedical research 1 6 Transfer Function Conversion Formula The analog sensor signals acquired with biosignalsplux devices are converted into digital valu...

Страница 6: ...place the electrodes and to connect electrodes cables for EOG acquisitions 1 8 Physical Characteristics W1 x L1 x H1 1 0cm x 1 8cm x 0 4cm W2 x L2 x H2 1 5cm x 2 3cm x 0 4cm A1 105 0 0 5cm A2 28 0 0...

Страница 7: ...e eye movements specifically vertical or horizontal movements 2 1 Reference Electrode For the positioning of the reference electrode it is recommended to be placed in an electrically neutral spot in t...

Страница 8: ...signal analysis The second configuration of the sensor is illustrated in Figure 6 This configuration is suited to measure horizontal eye movements as it measures the difference between the potential o...

Страница 9: ...t incompatible with the reference ground port Connect the sensor to an analog input to use it with this device Figure 7 EOG compatible biosignalsplux channels green checkmarks 3 1 2 biosignalsplux 8 C...

Страница 10: ...o the analog input channel of the biosignalsplux Solo openBAN 3 2 Configuring the Sensor in OpenSignals 3 2 1 OpenSignals r evolution Windows macOS Linux Open the OpenSignals r evolution device manage...

Страница 11: ...ical units using the above presented transfer function Figure 12 Set the channel type of the channel you have your EOG sensor connected to to EOG Activate the channel for acquisition by clicking on th...

Страница 12: ...Electrooculography EOG User Manual 12 of 17 Figure 13 Start the acquisition whenever you re ready...

Страница 13: ...ces or other approved accessories purchased from PLUX or by a PLUX agent The user should inspect the sensors on a regular basis to ensure that they remain in good working order The user should stop us...

Страница 14: ...10 C to 30 C Atmospheric pressure between 500hPa and 1060hPa Whenever the equipment needs to be transported it should be placed in the original box since this was designed and tested to ensure the eq...

Страница 15: ...nce Usage of the device that is not in accordance with the handling instructions indicated in the manual or use with accessories other than those manufactured by PLUX will invalidate the warranty of y...

Страница 16: ...agnosis cure mitigation treatment or prevention of disease we expressly disclaim any liability whatsoever for any direct indirect consequential incidental or special damages including without limitati...

Страница 17: ...mail plux plux info web http www plux info Headquarters Zona Industrial das Corredouras Lt 14 1 2630 369 Arruda dos Vinhos Portugal tel 351 263 978 572 fax 351 263 978 902 Lisbon Office Av 5 de Outubr...

Отзывы: