Up to four bandpass filters of wavelengths other than the standard can be fitted in the 

unit per request. Following wavelengths are available (see LEDs

’ spectral power specifica-

tion on figure 6): 

 

400 nm, 455 nm, 458 nm, 460 nm, 470 nm, 480 nm, 486 nm, 488 nm; 

 

500 nm, 508 nm, 510 nm, 515 nm, 520 nm, 532 nm, 535 nm, 540 nm, 546 nm, 
550 nm, 560 nm, 568 nm, 580 nm, 589 nm, 594 nm; 

 

600 nm, 610 nm, 632 nm, 636 nm, 640 nm, 647 nm, 650 nm, 656 nm, 660 nm, 
671 nm, 676 nm, 680 nm, 685 nm, 690 nm, 694 nm. 

 

Fig. 6. Relative spectral power in relation to wavelength for photodiodes  

(white and purple led maximum spectral power are not equal) 

 

Table 1. 96-well plate dimensions 

96-well plate 

Dimension (mm) 

Plate height 

14.35 

Plate length 

85.48 

Plate width 

127.76 

First well position X 

14.38 

First well location Y 

11.24 

Corner distance X 

99 

Corner distance Y 

63 

 

Optional accessories 

Description 

Catalogue number 

Verification microplate 

Microplate for annual verification of the unit 

BS-050108-AK 

Custom light filter 

Up to four custom filters in the unit 

Manufacturer is committed to a continuous program of improvement and reserves the 

right to alter design and specifications of the equipment without additional notice. 

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

300

350

400

450

500

550

600

650

700

750

800

850

Re

lat

iv

Sp

ectra

l Po

w

er

Wavelength (nm)

White LED

Purple LED

Содержание HiPo MPP-96

Страница 1: ......

Страница 2: ...2...

Страница 3: ...tents 1 Safety Precautions 4 2 General Information 5 3 Getting started 6 4 Operation 7 5 Unit verification 10 6 Specifications 12 7 Maintenance 14 8 Warranty and Claims 14 9 EU Declaration of Conformi...

Страница 4: ...power switch and external power supply are easily accessible during use Disconnect the unit from the external power supply before moving This equipment is connected and controlled by PC Please ensure...

Страница 5: ...BestFit function for the selection of the best calibration curve Multiplex analysis up to 7 different tests on the same plate Qualitative assays the ability to install up to 8 types of controls weak p...

Страница 6: ...pce Operating manual 1 copy Certificate of verification 1 copy Optional accessories Light filters custom 400 700 nm on request Verification microplate set on request Verification microplate set 3 3 Se...

Страница 7: ...A1 is placed next to the A1 label tag fig 3 1 Close the lid Note Measurements can be affected by uneven or heterogeneous well contents Visually inspect the plate for foaming opaqueness bubbles or part...

Страница 8: ...seconds 4 4 4 Press Start button The Measurement LED light fig 1 2 turns on Attention Do not open the lid during measurements 4 5 Measurement processing After an 8 second measurement the software aut...

Страница 9: ...mat press XLS 96 well button 4 9 After completing the measurements open the lid and remove the microplate then close the lid Attention Do not leave the microplate in the unit 4 10 After finishing the...

Страница 10: ...the certified verification plate Verification certificate is enclosed in the standard set and is valid one year from verification date All verification procedures must be performed only by qualified a...

Страница 11: ...channels to test fig 5 4 and the number of measurements to perform fig 5 2 We recommend a minimum of 20 measure ments Press the Start button fig 5 3 5 2 4 When measurements are finished press the Sho...

Страница 12: ...channel 1 6 9 Optical density measurement range 0 4 3 OD 6 10 Resolution 0 001 OD 6 11 Accuracy at 405 450 492 620 nm 0 000 2 000 OD 0 5 0 010 OD 2 000 3 000 OD 1 0 010 OD 6 12 Precision reproducibili...

Страница 13: ...imum spectral power are not equal Table 1 96 well plate dimensions 96 well plate Dimension mm Plate height 14 35 Plate length 85 48 Plate width 127 76 First well position X 14 38 First well location Y...

Страница 14: ...ments of Specifications provided the Customer follows the operation storage and transporta tion instructions 8 2 The warranted service life of the unit from the date of its delivery to the Customer is...

Страница 15: ...ctive 2014 30 EU LVD Directive 2014 35 EU RoHS2 2011 65 EU WEEE 2012 19 EU Applicable Standards LVS EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Gen...

Страница 16: ...Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Edition 1 07 January 2017...

Отзывы: