1.  Safety precautions 

The following symbols mean: 

 

Caution!

 

Make sure you have fully read and understood the present  Manual 
before using the equipment. Please pay special attention to sections 
marked by this symbol. 

GENERAL SAFETY 

 

Use only as specified in the Operating Manual provided. 

 

Do not use a dropped or damaged unit. 

 

Store and transport the unit in a horizontal position (see package label). 

 

After transportation or storage and before connecting to electric circuit, keep the unit 
under room temperature for 2-3 h.  

 

Before using any cleaning or decontamination methods except those recommended 
by the manufacturer, check with the manufacturer that the proposed method will not 
damage the equipment. 

 

Do not make modifications in design of the unit.  

ELECTRICAL SAFETY 

 

Connect only to electric circuit with voltage corresponding to that on the serial number 
label. 

 

Do not plug the unit into an ungrounded power socket, and do not use an ungrounded 
extension lead. 

 

Ensure that the power switch and plug are easily accessible during use. 

 

Disconnect the unit from the electric circuit before moving. 

 

Disconnect the plug from power socket to turn off the unit. 

 

If  liquid  penetrates  into  the  unit,  disconnect  it  from  the  electric  circuit  and  have  it 
checked by a repair and maintenance technician. 

 

Do not operate the unit in premises where condensation can form. Operating condi-
tions of the unit are defined in the Specification section. 

DURING OPERATION 

 

Do not impede the platform motion. 

 

Make sure that all sample vessels are tightly sealed. Humidity caused by evaporation 
from unsealed vessels inside the incubator will damage the unit. 

 

Do not operate the unit in premises with aggressive or explosive chemical mixtures. 
Please contact manufacturer for possibility of unit operation in specific atmosphere. 

 

Do not use outside laboratory rooms. 

 

Do not place a load exceeding the maximum load value mentioned in the Specifica-
tions section of this Manual. 

 

Do not operate the unit if it is faulty or has been installed incorrectly. 

BIOLOGICAL SAFETY 

 

It is the user’s responsibility to carry out appropriate decontamination if hazardous 
material is spilt on or penetrates into the equipment.  

 

Содержание ES-20/60

Страница 1: ......

Страница 2: ...2 Contents 1 Safety precautions 3 2 General Information 4 3 Getting started 4 4 Operation 6 5 Specifications 8 6 Maintenance 9 7 Warranty and Claims 10 8 EU Declaration of Conformity 11...

Страница 3: ...and plug are easily accessible during use Disconnect the unit from the electric circuit before moving Disconnect the plug from power socket to turn off the unit If liquid penetrates into the unit dis...

Страница 4: ...on and temperature regulation PID control decrease the energy consumption and make the shaker incubator highly energy efficient despite its relatively large size 3 Getting started 3 1 Unpacking Remove...

Страница 5: ...ort its weight remove protective film from the display plug the power cord into the socket on the rear and position the unit so that there is easy access to the power switch and plug 3 4 Platform inst...

Страница 6: ...s required The set parameters can also be changed during oper ation 4 3 1 Setting time Time Using the and Time keys Fig 1 1 set the required work ing time interval in hours and minutes increment 1 min...

Страница 7: ...g the RPM Run Stop key will start continuous operationof the unit with countdown timer in the lower line and indication OFF in the upper line until the RPM Run Stop key is pressed again Caution At the...

Страница 8: ...ng voltage power consumption 230 V 50 60 Hz 450 W 2 A or 120 V 50 60 Hz 450 W 4 5 A Weight 41 1 kg Optional ac cessories Description Catalogue number P 30 100 Platform with clamps for 30 flasks of 100...

Страница 9: ...ning agents recommended for cleaning and de contamination of the stainless steel surfaces 6 3 2 For decontamination it is recommended to use a special DNA RNA removing solu tion e g DNA Exitus PlusTM...

Страница 10: ...ess To obtain the claim form visit section Technical support on our website at link be low 7 5 Extended warranty For ES 20 60 a Premium class model one year of extended warranty is available free of c...

Страница 11: ...laboratory use EMC requirements General requirements LVS EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use General requirements LVS EN 61010 2 010...

Страница 12: ......

Отзывы: