26
Value limits, sec:
1 – 99.
Change of supply (delivery) time during flame start-up is intended for setup of
ideal time for fuel ignition during the first flame start-up. Large amount of fuel will
result in great smoke spread, increased time for flame start-up. Insufficient amount of
fuel will result in fast burnout of the initial portion, and loss of fire in the burner.
!ATTENTION!
IT IS PROHIBITED to open the boiler door during flame start-up and great smoke
spread in the combustion chamber.
Picture 19 – Fuel Delivery Setup Window (flame start-up)
4.2.4 Internal Screw
To enter the internal screw parameter change window it is required to select
menu item «Internal Screw»,
, in the flame start-up menu and press the button. The
current parameter value will be displayed in the popped up window.
Parameter value change is similar to item 3.3.2, the difference is that these
values are used in the flame start-up process only.
4.3 Pump Switch-On Temperature
Pump switch-on temperature and hysteresis of switch-off are set up in this
menu.
To enter the menu «Pump Switch-On Temperature» it is required to select menu
item «Service Menu»,
, in the main menu, and press the encoder button, and enter
code
2222
in the popped up window (Picture 16)
.
Select item «Pump Switch-On