background image

TABLE OF CONTENTS

Page

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

pH BOSS ILLUSTRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

ACID SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

pH BOSS INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

TEE PIECE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

pH Probe Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

CONTROL BOX INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

ACID PUMP HOSE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

TEE PIECE HOSE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

DRUM WEIGHT HOSE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

pH PROBE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

PROGRAMMING YOUR pH BOSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

AUTO / OFF KEY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

DOSE SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

MANUAL DOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

CHANGING THE pH SET POINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

ALARM FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

pH PROBE CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

PUMP SQUEEZE TUBE LUBRICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

PUMP SQUEEZE TUBE REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

BIONIZER CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

CONTENTS

2

Содержание PH BOSS

Страница 1: ...TM INSTRUCTION BOOK Automatic Pool pH Control System Please read before you call us for advice Version 1 51d 07 Nov 2017 bionizer com au bionizer com DOWN UP AUTO OFF CANCEL PROGRAM SET TM...

Страница 2: ...PUMP HOSE INSTALLATION 8 TEE PIECE HOSE INSTALLATION 9 DRUM WEIGHT HOSE INSTALLATION 9 pH PROBE INSTALLATION 9 PROGRAMMING YOUR pH BOSS 10 AUTO OFF KEY 10 DOSE SETTING 10 MANUAL DOSE 11 CHANGING THE p...

Страница 3: ...uted acid every weekortwo So the pH BOSS saves you time frustration AND money Before installing the pH BOSS the pool water should be correctly balanced particularly total alkalinity The pH BOSS can be...

Страница 4: ...grammingmenus Presstoscrollthroughthefiveusersettingmenus Presstosavechangeswhenadjustingsettings OK pHreadingiscorrect asperSetPointsetting Add pHreadingisaboveSetPoint pH BOSS dosingpumpwillrun whil...

Страница 5: ...e pH BOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the pH BOSS and will void your warranty 1 WARNING alwaysusedilutedacidat1partacid to4ormorepartswaterwithpH BOSS 2 ALW...

Страница 6: ...installed fitthepH BOSS tee BEFORE the Salt Chlorinator cell The acid will help to keep the expensive Chlorinator cellsclean If a liquid Chlorine injection system is fitted install the tee BEFORE the...

Страница 7: ...mvertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE pH PROBE HORIZONTAL WHICH WILL RENDER THE pH PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount on ve...

Страница 8: ...easily Fix the control box in position usingscrewsateachcornerofthebox NOTE Make sure that the pH BOSS is positioned near enough to a power outlet and to the T piece and acid drum to allow the power c...

Страница 9: ...to the Tee piece thread Tighten firmly by hand DO NOT OVER TIGHTEN DO NOT USE A TOOL 3 After the pH Probe is installed in the Tee piece connect plug on the pH Probe cable into the probe socket on the...

Страница 10: ...terto1partacid page5 For pools with a wet edge and balance tank use a settingof1lowerthanlistedforthepoolsize If the pH BOSS does not keep up with acid demand and the Alarm sounds increase the dose se...

Страница 11: ...x Re calibratethepHProbe Seepage12 Problem pHProbeisbrokenorfaulty Fix If re calibration is not possible then replacethepHProbe Seepage9 A replacement pH Probe can be ordered by telephone or online at...

Страница 12: ...ationjar seepicture ontheright Fill the Buffer Jar to the 250mL mark with distilled water Filtered tap water canalsobeused Replace both the seal and thelid thenshakewellfor 1 minute to ensure that t h...

Страница 13: ...topH BOSS whendone Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestartingthisprocedure Switchyourpoolequipmentbackon If using a Bionizer ensu...

Страница 14: ...he pump rotor a little and place the squeeze tube between the pump body and the two rollers Push the squeeze tube and rotor into the pump body Ensure that the inlet and outlet are seated in theguideso...

Страница 15: ...er Faulty AC DC poweradaptor Replacepoweradaptor PleasecontactyourdistributororBionizer FaultypH BOSS mainunit ReturntoBionizerforrepair DoseSettingissettoohigh ReducetheDoseSettingbyonelevelandchecki...

Страница 16: ...dale Rd Suite 410 Scottsdale AZ 85254 USA Phone 1 480 696 2387 Toll Free 1 855 8 IONIZE Email relax bionizer com Web bionizer com Bioniser Pty Ltd 1 173 Bradman Ave Maroochydore QLD 4558 Australia Pho...

Отзывы: