4. Time format 12/24H selection

With the time format blinking, press the main 
button to adjust it. Then hold the same button 
for 2 seconds to confirm it and move to hours 
setting.

5. Hour setting

With the hour blinking, press the main button until the current 
hour appears. Then hold the same button for 2 seconds to 
confirm it and move to minute setting.

6. Minute setting

With the minute blinking, press the main button  
to adjust it. Then hold the same button for 2 
seconds to confirm it. Meantime, it will shift to 
next digit for setting. Repeat the above action 
until the minute setting is completed. Then it will 
move to average-day setting.

7. Average-day setting

With the number " 1, 7, 14, 30 " blinking, press 
the main button for the days of the average you 
would like to read. Then hold the same button 
for 2 seconds to confirm it and move to 
measurement unit setting.

8. Setting the unit of measurement

With milligrams per deciliter (mg/dL) or 
minimole per liter (mmol/L) blinking, press the

9. Ending setting

After confirm the measurement unit, you'll hear a sound of " beep ". All the 
settings are saved and completed and will return to time screen.

1. Year setting

    

With the year format blinking, press the main button to adjust 
it. Then hold the same button for 2 seconds to confirm it. 
Meantime, it will shift to next digit for setting. Repeat the above 
action until the year setting is completed. Then it will move to 
month setting.

2. Month setting

    

With the month blinking, press the main button until the 
current month appears. Then hold the same button for 2 
seconds to confirm it and move to day setting.

3. Day setting

    

With the day blinking, press the main button to adjust it. Then 
hold the same button for 2 seconds to confirm it. Meantime, it 
will shift to next digit for setting. Repeat the above action until 
the day setting is completed. Then it will move to time format 
setting.

NOTE 

When you do not do any settings of meter for over 2 minutes, the meter 
will leave setting mode and power off automatically.

Any time you would like to escape from the setting mode, please press 
and hold the main button for over 5 seconds. Meantime, all the current 
settings will be saved.

 main button to switch. Then hold the same button for 2 seconds to confirm it.

PRECAUTION

- Re-cap the test strip the vial immediately after removing a test strip.
- Do not reuse test strips.
- Do not use expired test strips.
- Record the date of opening a new strip vial for the first time. Discard the  
  vial of strips after 3 month from opening.
- Store the test strips in a cool and dry location. Do not expose to direct 
  sunlight or heat.
- For detailed information, please refer to the                    

GS100

 

Test Strip  

  Package Insert.

Intended Use

Blood Glucose Monitoring System

Instructions for Use

The                    Blood Glucose Monitoring System is intended for in vitro 
diagnostic use ( for self-testing ) only ( outside the body ) and 

coding

 

is

 

not 

required

. The testing result is calibrated to be plasma equivalent for test with 

fresh capillary whole blood samples from the fingertip, palm or forearm 
depends on what kind of lancing device you are using. You may consult your 
healthcare professional for instructions on how to use the system correctly. Our 
customer support staff is available to assist you as well.

1.

Package of Meter Kit

2.

Preface

1

( Different packages have different bundled items. Some of packages might not 
  include 

 items.)

The                   Meter

3.

Precautions

4.

Before using the                    System to test your blood glucose, please read 

all the instructions and practice the tests including quality control test. 

Please do the quality control test regularly to make sure the test results are 

  

accurate .

The                    GM100 Blood Glucose Meter can only be used with the

                     GS100 Blood Glucose Test strips. The use of any other brand 

strips should not be used under any circumstances. The use of other brands 
of strips may produce inaccurate results.

The                   Blood Glucose Monitoring System is intended for self-testing. It 

should not be used to diagnose diabetes mellitus.

-                    

Blood Glucose Monitoring System has not been validated for use 

on neonates. Therefore, it's not intended for use of neonates.

- This meter can be only tested with capillary whole blood. Please don't test with 

arterial blood.

Do the test at least 30 minutes after moving into a different location with 

significant change in temperature.

- Dispose of used batteries properly.
- Please note the meter kit contains small parts like test strips which could result 

in a choking hazard for children.

- Prevent water from entering the meter. Never immerse the meter or hold it 

under running water.

- The minimum blood sample size for testing is 1.4µl :(    ) 

Sample Size Example

1.0             1.4               2.0              3.0

µl

µl

µl

µl

4 µl

              .0

The                   Test Strip ( GS100 Test Strip )

5.

Sample Entry

µl

Apply a drop of blood or control solution 
here. The test request is only 1.4  of blood. 

Electrode Contacts

Sensing signal output terminals. 

Noble Metal Electrodes

Electrochemical sensor

Indication Symbol

Insert strip with indication symbol 
up and toward meter.

Battery Installation

6.

10. While the blood drop symbol flashing, you are ready to apply the blood 

sample. 

11. Place the lancing device against the pad of 
      your fingertip and press the release button. 
      The best puncture sites are on the middle or 
      ring fingers. Press the release button.

14. Pull off the depth adjustable cap. Without touching the used disposable 

lancet, stick the lancet tip into the protective cover.

15. Hold the release button in one hand and pull on the plunger in the other 

hand will safely eject the used disposable lancet.

16. Discard the used disposable lancet into an appropriate puncture-proof or  

      

biohazard container.

17. Replace the depth adjustable cap after finishing the test.

12. Touch and hold the drop to the edge of 

sample entry until you hear a " beep " and the 
view window is totally filled with blood. If the 
view window is not totally filled with blood or 
the test does not start. Please discard the test 
strip and repeat the test with a new test strip.

13. You will see the countdown mode on the 

screen. After 8 seconds, the test result 
appears.

1

2

The                    Blood Glucose Monitoring System was manufactured by 
supported by Bionime Corporation and its authorized representative. If you 
have any questions or concerns, please contact your Bionime authorized 
representative or call us by phone number, 886 4 24951268 ( GMT+08:00, 
08:30~17:30 ). We will provide best assistance and solutions for you. 

Hand Bar

Grip here to insert 
test strip into meter.

View Window

This window is yellow before applying 
blood sample. It gradually turns red 
when filled with blood.

We suggest you use a sample between 1.4~2.5µl. A blood sample size above 
4.0µl is too large. A blood sample size below 1.4µl may give an inaccurate test 
result. In this case, repeat the test with a new test strip.

                   

GM100

 is designed to use with 

GS100

 strip only. Please note that 

misuse of other strips might cause unexpected damage or produce 
inaccurate test results.

Thank you for selecting the 

Blood Glucose Monitoring System. 

Please read this manual thoroughly before you start testing. It provides all the 
information you need to use the product. You will get a correct test result by the 
following instruction of this manual. 

Please only purchase the test strips in 

your country, the use of the test strips of different countries is not 
suggested and might get deviated test results under such circumstance.

It is quite important for you to monitor blood glucose regularly. A derived 
complication can thus be effectively reduced. Through the assistance of
                   Blood Glucose Monitoring system, which provides considerate 
design and accurate results, your diabetes management can become more 
reliable and ease-to-use.

                   

Display Window

Show your test result, 
messages and relative 
information.

Test Strip Port

Insert test strip here until you 
hear a click.

Main Button

Press to turn on/off meter.
Switch different function 
screen.
Press and hold down until 
enter to the setting mode. 
(There will be a power-off 
period during this process.)

Battery Cover

Slide cover to 
change battery.

Meter Serial 
Number

Model Number

Plastic Tape

Pull it off to activate meter.

Test Strips

2007

-

06

1.                    Meter
2.                     Test Strips (0/10/25 pcs) 

*

3.                    Control Solutions 

*

4.                    Instructions for Use
5.                    Blood Glucose Test Strip  
    Package Insert 

*

    

6.                     Lancing Device 

*

  7. Disposable Sterile Lancets 

(10pcs) 

*

  8. Instruction for the lancing device 

*

  9. Log Book
10. Warranty Card + Emergency
11. CR2032 Battery (Inserted into the 

meter)

12. Carrying Case 

*

 

4

9. Insert the strip into the strip port on meter with the indication symbol facing  

up.

11

10

13

16

14

15

17

Setting Up Your Meter-Setting the Date, Time, and Unit 

……

7.

PRECAUTION

Danger of explosion might happen if the battery is incorrectly replaced.

Please follow the local regulation and discard a used battery properly.

6. Set the time and date when the batteries are replaced. See Setting the Date, 

Time and Unit section. Prior test results are still stored in the memory.

Your meter comes with one CR2032, 3volt, battery installed. One 
new battery will provide power to perform about 1000 tests under 
normal use. Before using it, please pull off the plastic tape and 
press the main button to activate the meter. The low battery 
symbol "        " will keep appearing on your display if your battery 
runs low. Please keep spares on hand and replace the battery 
soon when a battery symbol appears.

1. Turn the meter over. Press and push battery 

cover to open.

2. Install the battery. Be sure to put battery in 

correct direction.

3. Slide the battery cover back until it snaps into place.
4. The meter performs a self-test and all symbols on the display 

will blink.

5. Press any button to exit the self-test and enter Setting Mode.

5. Choose a depth of penetration by rotating the 

top portion of the depth adjustable cap until 
the setting depth matches the window. 
Settings are based on skin type "       " for soft 
or thin skin; "      " for average skin; "      " for 
thick or calloused skin.

1. Pull off the depth adjustable cap.
2. Insert a new disposable lancet firmly into lancet carrier.
3. Twist off and set aside the protective cover of the disposable lancet.
4. Replace the depth adjustable cap. 

6. Hold the hub in one hand and pull on the plunger in the other hand. The 

device will be cocked. Release the plunger, it will automatically move back to 
its original position near the hub.

1

2

3

4

5

6

7. Wash your hands with warm 

soapy water and dry thoroughly.

8. Take one strip from the vial. Re-

cap the vial cap immediately.

7

8

9

Performing a Blood Test

8.

Hub

Lancet carrier

Plunger

Release button

Depth adjustable cap

You can enter Setting Mode by below two ways.
1. Reload battery

    

After removing the battery, please press the main button for several times 
until no signal on screen, then follow the battery installation steps to load 
battery. The meter will do self test. Press the main button to close the test 
and enter Setting Mode.

2. With Battery inserted

    Press the main button first to turn on the meter. Then press and hold the main 

button for 5 seconds (the meter will be turned off during this period, please 
keep pressing) until you hear a beep, indicating you have successfully 
entered Setting Mode. The display screen will show setting data.

NOTE

When you keep pressing the main button for 2 seconds, the display on 

screen will turn off. Please don't care it. Keep pressing the main button 
till entering setting data.

Quick press the main button allows you to change setting while hold it 

for 2 seconds will confirm the setting. However, if you press and hold 
the main button over 5 seconds it will escape from setting mode and 
return to time screen.

Turning on /off the Meter

1. Auto Power off

    The meter will power off automatically if you don't operate it over 2 minutes.

2. Manual Power off

    If you want to turn off the meter, please keep pressing the main button for 2   
    seconds.

3. How to turn on the Power

    1) Press the main button
    2) Insert one piece of test strip

PRECAUTION

Do not touch your blood drop to the sample entry on the strip until you
see the "     " appear. The meter is performing an internal test and will
display "     " and "          " if you apply blood too soon. Then you will waste 
a test strip.

12