background image

7

8

CLEANING AND MAINTENANCE

Before cleaning, please note the following:

• DO NOT use soap, detergents, abrasives, gasoline, glass

or furniture polish, or boiling water to clean any part of your
humidifier. These will interfere with the proper operation of
your humidifier.

• DO NOT use sharp or metal objects to clean mineral

deposits in the tray or element. Contact with sharp 
objects can result in damage to the plastic.

• We recommend that the tray be rinsed daily and that the

unit be allowed to run out of water every second day.

• Mineral deposits should be soaked in BIONAIRE

®

’s 

Clean-Away

®

solution or plain vinegar. DO NOT 

operate unit while it is soaking!

• DO NOT clean any part of your humidifier in the dish washer.

• NEVER mix bleach and Clean-Away

®

solution.

Cleaning instructions:

1. Turn the unit off and unplug it.

2. Remove the water tank; then, unlock the misting chamber

by rotating the latch (Figure 6) and lift it from the unit’s
base. Now lift the tray from the base (Figure 7).

3. Empty water and minerals from the tray and fill with 

Clean-Away

®

solution. Replace the tray and misting 

chamber in the base. (This will submerse the element in
the cleaning solution). Soak for a minimum of 20 minutes 
to a maximum of 30 minutes. 

4. Rinse the tray and heating element with clean warm water.

All traces of Clean-Away

®

on both the element and the tray

must  be thoroughly rinsed off before disinfecting. Inspect
the heating element (see Figure 8) for scale buildup. If
present, please see “Special Maintenance - Heating
Element” for further cleaning instructions.

NOTE: DO NOT ALLOW WATER TO ENTER THE AIR 
OUTLET GRILL OR ANY OTHER OPENINGS.

Figure 6

Figure 7

Misting Chamber

Tray

Latch

5. Disinfect the water tank and tray using a solution of one

teaspoon of chlorine bleach in 1 gallon of water. Let solution
soak for 20 minutes, swishing every few minutes to wet all
surfaces. Empty the tank and tray; rinse thoroughly until
bleach smell is gone. Replace the tray in the base (Figure 7),
then replace the misting chamber in the unit, making sure
that the latch has been locked in position. Fill the 
tank with fresh water and replace it into the unit.

6. Resume normal use.

SPECIAL MAINTENANCE - HEATING ELEMENT

Should the output drop or the
“EMPTY/CLEAN” light illuminate with
water remaining in the tank, it will be
necessary to remove scale buildup 
on the heating element. Remove the
misting chamber by rotating the latch

and lift it from the unit’s base. Place the misting chamber on
its side. The heating element will now be visible (Figure 8).
Using a non-metallic brush, scrape away the scale buildup
on the element. Follow steps 3-6 to complete cleaning.

Note:

The above special maintenance is required due to

water hardness. The harder your water, the more often this
special maintenance will be needed.

AFTER SEASON CARE

If you do not plan to use your humidifier for an extended 
period of time (i.e. during the summer months), it is important
that you follow these instructions to help prevent stagnation of
water in the unit.

1. Clean your humidifier as instructed in the section titled

“Cleaning and Maintenance”.

2. Make sure all water is emptied from the tank and tray.

3. Dry your unit thoroughly.

4. Leave the tank cap off allowing the tank to be 

exposed to air.

5. Store humidifier in a cool, dry location.  Bionaire

®

recommends storing the unit in its original box.

Figure 8

Heating Element

Содержание CP0260

Страница 1: ...P0260 Read instructions before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on your humidifier call 1 800 78...

Страница 2: ...rning may cause personal injury Be sure to pull by the plug and not the cord 7 NEVER drop or insert any object into any openings DO NOT place hands face or body directly over or near Outlet Grill whil...

Страница 3: ...attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged Serious injury may result 15 This humidifier requires daily and weekly maintenance Refer to daily a...

Страница 4: ...and skin Excessive dryness can also damage furniture carpets and fabrics Warm Moisture humidifiers put moisture back into the air you breathe to help relieve sinus and respiratory discomforts reduce a...

Страница 5: ...button to reactivate the humidifier this will also extinguish the EMPTY CLEAN light Note Allowing your humidifier to run out of water before filling the tank helps to self clean the heating element SE...

Страница 6: ...walls or windows lower the setting or turn off the humidifier FILLING THE WATER TANK When the water tank is empty the EMPTY CLEAN light will illuminate and no moist air will be produced until the wate...

Страница 7: ...to be replaced or become damaged or lost replacements may be ordered directly from BIONAIRE by visiting our website at www bionaire com or calling 1 800 788 5350 The filter is located behind the inlet...

Страница 8: ...inerals from the tray and fill with Clean Away solution Replace the tray and misting chamber in the base This will submerse the element in the cleaning solution Soak for a minimum of 20 minutes to a m...

Страница 9: ...water remaining in the tank it will be necessary to remove scale buildup on the heating element Remove the misting chamber by rotating the latch and lift it from the unit s base Place the misting cham...

Страница 10: ...ere you purchased it If you are returning the unit more than 30 days after the date of purchase please see the enclosed warranty 3 Should your humidifier require service please call 1 800 788 5350 in...

Страница 11: ...or alteration of the product BIONAIRE EXPRESSLY DISCLAIMS ALL RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES CAUSED BY USE OF THIS PRODUCT The provisions of this warranty are in additi...

Отзывы: