background image

3

4

be maintained while the unit is in operation. 
RESET Button (“RESTART”) - This control resets the humidifier
after it has shut down due to an empty water tank or after 
it has been cleaned. The “RESTART” button needs to be
pressed after each filling/ cleaning. The “EMPTY/CLEAN” 
light will remain illuminated after refilling until the “RESTART”
button is pressed.

OPERATING INSTRUCTIONS

1. Place your humidifier in the desired location. A hard, level,

waterproof surface is necessary for proper operation. Do
not place your humidifier on any surface that could be
damaged by water droplets.

2. Check that the Automatic Humidistat control is in the 

“OFF” position.

3. Remove the water tank and fill it with water as directed

under the heading “Filling the Water Tank.” Make sure that
the removable tray is in place and the misting chamber is
latched. Place the water tank back in the unit and allow 
one minute for the water to fill the tray.

4. Plug the power supply cord into the most convenient 

120V AC wall outlet.

5. Turn your humidifier on by rotating the Automatic Humidistat

control to your desired comfort level. For details, see the
section titled “Setting the Automatic Humidistat Control.”

6. When all the water in the tank has been used, the “EMPTY/CLEAN”

light will illuminate. After refilling the tank, it is necessary to
press the “RESTART” button to reactivate the humidifier;
this will also extinguish the “EMPTY/CLEAN” light.

Note:

Allowing your humidifier to run out of water before 

filling the tank helps to self-clean the heating element.

SETTING THE AUTOMATIC HUMIDISTAT CONTROL

Adjust the Automatic Humidistat control as desired. The unit
has been designed to operate within a range of approximately
20% to 80% R.H. (Relative Humidity). The most favorable 
setting for home or office environments is 40% to 45% R.H.

To monitor the actual humidity level in a room, we recommend
the use of a humidity meter such as the Bionaire

®

BT400 or

BT254 Digital Humidity and Temperature Monitor.

The Automatic Humidistat works in the following manner:

• Whenever the humidity in the room is less than the level 

you have set, moist air is dispersed from the outlet grill.

The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping over a
longer cord. If a longer cord is necessary an approved extension
cord may be used. The electrical rating of the extension cord
must be equal to or greater than the rating of the humidifier.
Care must be taken to arrange the extension cord so that it 
will not drape over the countertop or tabletop where it can 
be pulled on by children or accidentally tripped over.

HOW YOUR WARM MOISTURE HUMIDIFIER WORKS

Lack of humidity in the air, often caused by winter heating, can
dry out your nose, throat and skin. Excessive dryness can also
damage furniture, carpets and fabrics. Warm Moisture humidifiers
put moisture back into the air you breathe to help relieve sinus
and respiratory discomforts, reduce annoying static electricity
and provide a healthy growing environment for your indoor plants.

Water is fed from the
tank into a removable
tray in which a constant
water level is maintained.
This tray collects some
of the minerals that form
on the heating element.
The minerals can be
rinsed from the tray when
the tank runs out of

water (See “Cleaning and Maintenance”). Air is drawn in
through the grill openings and air filter located on the side 
of the unit and mixes with steam in the misting chamber. 
The warm mist is then dispersed out of the top of the 
misting chamber through the outlet grill.

The unit is conveniently refilled with water by taking only the
removable water tank to a water tap. A suitable medication 
can be placed in the medication cup and warmed. 

CONTROL PANEL

POWER Light-When illuminated, 
indicates that the power is on.
LOW WATER INDICATOR Light
(“EMPTY/CLEAN”) - When illuminated,
indicates that the water tank needs

refilling and/or that the tray and heating element need cleaning.
See the “Cleaning and Maintenance” section for more information.
AUTOMATIC HUMIDISTAT Control - This control allows you to
select the desired humidity level which will automatically 

Control Panel

Air Filter

Misting

Chamber

Lift-Out-And-Rinse Tray

Tank Cap

Removable and

Transparent Tank

Removable Outlet

Grill - Access to
Medication Cup

Figure 2

Figure 1

Содержание CP0260

Страница 1: ...P0260 Read instructions before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on your humidifier call 1 800 78...

Страница 2: ...rning may cause personal injury Be sure to pull by the plug and not the cord 7 NEVER drop or insert any object into any openings DO NOT place hands face or body directly over or near Outlet Grill whil...

Страница 3: ...attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged Serious injury may result 15 This humidifier requires daily and weekly maintenance Refer to daily a...

Страница 4: ...and skin Excessive dryness can also damage furniture carpets and fabrics Warm Moisture humidifiers put moisture back into the air you breathe to help relieve sinus and respiratory discomforts reduce a...

Страница 5: ...button to reactivate the humidifier this will also extinguish the EMPTY CLEAN light Note Allowing your humidifier to run out of water before filling the tank helps to self clean the heating element SE...

Страница 6: ...walls or windows lower the setting or turn off the humidifier FILLING THE WATER TANK When the water tank is empty the EMPTY CLEAN light will illuminate and no moist air will be produced until the wate...

Страница 7: ...to be replaced or become damaged or lost replacements may be ordered directly from BIONAIRE by visiting our website at www bionaire com or calling 1 800 788 5350 The filter is located behind the inlet...

Страница 8: ...inerals from the tray and fill with Clean Away solution Replace the tray and misting chamber in the base This will submerse the element in the cleaning solution Soak for a minimum of 20 minutes to a m...

Страница 9: ...water remaining in the tank it will be necessary to remove scale buildup on the heating element Remove the misting chamber by rotating the latch and lift it from the unit s base Place the misting cham...

Страница 10: ...ere you purchased it If you are returning the unit more than 30 days after the date of purchase please see the enclosed warranty 3 Should your humidifier require service please call 1 800 788 5350 in...

Страница 11: ...or alteration of the product BIONAIRE EXPRESSLY DISCLAIMS ALL RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES CAUSED BY USE OF THIS PRODUCT The provisions of this warranty are in additi...

Отзывы: