background image

GREYWATER FILTER LIGHT

User manual

FI

SV

EN

RU

Содержание GREYWATER FILTER LIGHT

Страница 1: ...GREYWATER FILTER LIGHT User manual FI SV EN RU ...

Страница 2: ...or by pumping no septic tanks required The treatment capacity of one module is about 300 litres per day Content Component list 2 Component drawing 2 1 Planning and installation 3 1 1 Technical specifications 3 1 2 Location out of doors 3 1 3 Location inside a residential building 3 1 4 Air circulation 3 1 5 Conducting wastewater to the filter 4 1 6 Discharge point for the wastewater 4 1 7 Putting th...

Страница 3: ...704051 PP 8 inlet pipe end 18715250 PE 9 latch 18710370 EPDM 10 washer for latch 18726140 PE 11 lead through rubber 75 mm black 2 pcs 18001001 EPDM In addition to the components illustrated in the components picture the Greywater Filter light also includes crosshead screw M5x25 A4 20040026 RST nut nylock M5 20020009 RST fender washer A2 M5 20060002 RST sealing band 12 4mm 2 5 m 19776001 EPDM cell ...

Страница 4: ...l not gather even when there is flooding The filter can be installed out of doors without a cover The unit has no thermal insulation If the unit is used also in winter it must be located in a space where the temperature stays above zero at all times 1 3 Location inside a residential building If you are planning to install the filter indoors or in close prox imity to a residential building for example...

Страница 5: ... sewer outlet of the house all the way to the discharge point No septic tank required The module is fitted with inlet and outlet connectors for a 75 mm sewer pipe The inlet connector is located at the upper edge of the module and the outlet connector at the lower edge It is pos sible to connect two modules in series or in parallel Serial connection The sewage pipe coming out of the building is conn...

Страница 6: ...ist and the exiting water is clear and odourless and does not contain a significant amount of solid matter Check that 1 wastewater is flowing smoothly from all the openings of the box 2 the filter material has been drawn to a distance of about 5 cm from the openings in the discharge end of the box 3 the visible connections of the sewers are in order 4 the purified wastewater is flowing freely out of th...

Страница 7: ... five years 1 The guarantee is valid from the date of purchase and covers possible defects in material and workmanship The guaran tee does not cover any indirect damage 2 Biolan Oy retains the right to decide about repairing or re placing damaged parts at its discretion 3 Any damage resulting from careless or forcible handling of the device from failure to observe the operating instruc tions or fro...

Страница 8: ......

Отзывы: