Manual - BioSpot BT600 workstation 

 

 

page 4 of 15 

1.4

 

Intended use 

The BioSpot BT600 workstation (complete machine) 

is intended to be used accordingly to the 

installed components. This means that the designated use, with respect to the Machinery Directive 
(published by the European Commission in 2006, section 1.1.2) is generally defined by the installed 
components (e.g. PipeJet dispenser).  

Considering this premise, the BioSpot BT600 may be applied for dosing liquids, coating surfaces, to 
measure two dimensional geometries or for aspirating liquids.  

The BioSpot BT600 workstation is intended for the following uses considering following guidelines:  

 

positioning of print heads and dosing units which are authorized to be used with 
the system by BioFluidix 

 

the BioSpot BT600 is intended for indoor use in a laboratory or industrial 
environment only 

 

the BioSpot BT600 is to be operated by skilled personnel who are familiar with 
the user’s manual only. 

The BioSpot BT600 workstation without installed components (incomplete machine) 

may be 

extended to a complete machine by the customer, when adding any of the authorized components 
(please contact BioFluidix) to a complete machine. Thereby, the customer needs to follow the 
currently effective Machinery Directive. Furthermore, the customer is in this case responsible for 
certificating the final device in purpose of own use or distribution. 

Other use as listed is not allowed and will lead to damage of the BioSpot BT600. The whole product 
may not be changed or reconstructed. 

1.5

 

Reasonably foreseeable misuse 

 

Use of non-authorized print heads or dispensers 

 

Installation and use of different tools or components 

 

Use of harmful or dangerous  liquids 

 

Applications which are not following the declaration of conformity 

 

Operation by non-skilled personnel 

 

 

Содержание BioSpot BT600

Страница 1: ...BT BioFluidix GmbH Engesserstra e 4a D 79108 Freiburg Germany www biofluidix com User Manual BioSpot BT600 Version 1 1 Date March 2018...

Страница 2: ...ist of parts 5 5 Description of the BioSpot BT600 6 5 1 BioSpot BT600 workstation 6 5 2 Connectors at the control electronics located at the z axisFehler Textmarke nicht definiert 5 3 Backside connect...

Страница 3: ...es on cables or damages on mechanical parts If it is supposed that it is not possible to launch a safe operation you have to take it out of service and protect it against an unintended operation It is...

Страница 4: ...into the BioSpot BT600 device It is prohibited to store or place any object on the platen of the BioSpot BT600 which is not in the purpose of use Keep your hands away from all moving elements during o...

Страница 5: ...a laboratory or industrial environment only the BioSpot BT600 is to be operated by skilled personnel who are familiar with the user s manual only The BioSpot BT600 workstation without installed compo...

Страница 6: ...e in outdoor environment Use the device indoors in clean and dry environment The installation base needs to offer a stationary even and robust surface It must resist the appearing acceleration forces...

Страница 7: ...igure 1 Photograph of the BioSpot BT600 workstation indicating the most important functional parts Dispenser connection Plug socket to connect a dispenser e g up to eight PipeJet dispensers Warning Hi...

Страница 8: ...mponents from the power supply except the internal PC and the power switch on the back side The emergency switch can be used to stop non intended movement of one of the axis or non intended dosage PLE...

Страница 9: ...re essential methods to improve or support the development of the desired dosing process or be applied to implement process control Possible accessories are listed and explained in the following TopVi...

Страница 10: ...control by correlation of generated signals Pressure controlled reservoir o guarantees constant pressure at the dosing nozzle o improves long term stability of the dosing process o enables big reservo...

Страница 11: ...socket 90 240V o Fuse 6A B C characteristic 3 Make sure the emergency switch is unlocked 4 Switch the backside power toggle switch to 1 on to start the BioSpot BT600 o the internal PC will start up au...

Страница 12: ...into the substrate holder Move reservoir holder down and fix it with the allen key Connect Tygon ND 100 65 to the intermediate reservoir using the black rubber adaptors and the Serto aspiration connec...

Страница 13: ...on of the device you can request for the original set of registry entry by BioFluidix 7 2 Interfaces Ethernet socket Typ RJ45 Transfer rate 10 100 1000Mbit s USB 2 0 USB connectors DVI connector Conne...

Страница 14: ...nsions w x l x h 550 mm x 636 6 mm x 539 2 mm Weight 32 kg depending on the individual configuration Environmental operation conditions Temperature 10 C 30 C Humidity 10 80 non condensing conditions 7...

Страница 15: ...ispensing the BioSpot BT600 workstation check for contaminations of hazardous or environmental and health threatened substances that may have been formed during use and remove them if required Dispose...

Страница 16: ...stions or comments please contact BioFluidix GmbH Engessertsra e 4a D 79108 Freiburg Germany phone 49 761 458938 0 fax 49 761 458938 99 e mail info biofluidix com Internet www biofluidix com Freiburg...

Отзывы: