Troubleshooting
Since the battery can be used in many different configurations and equipment, we cannot provide
a general troubleshooting guide. Please contact us so a technician can provide you with
individualized support.
FAQ
Q. The terminals/connectors on the battery do not fit my application, what do I do?
A. You can change the terminal/connector to whatever type you need without voiding the warranty
so long as you do not open the battery or modify the casing.
Q. I have a universal lead acid charger with high charging current, can I use it instead?
A. Not recommended. Lead acid battery charges at 2.30V to 2.45V per cell whereas LiFePO4
needs 3.60V per cell. Your battery would be undercharged so you won’t get full capacity nor
will balancing be triggered, both of which are not desired. Furthermore, the floating charge of the
lead acid charger is not expected by the battery and can cause problems.
Q. How come the battery stops working a few seconds after a high current draw?
A. Make sure the load is not exceeding the rated continuous output current else the PCM shuts off
the battery after 2 sec. To reset, disconnect the load and attach the charger for a few seconds.
If you need more current output, please contact us for an exchange or a custom solution.
Q
.
Can I buy another of the same LiFePO4 battery to double the voltage or capacity?
A. Not recommended. Refer to the series and parallel connection section. You should always get a
single battery that meets your voltage and capacity requirements to avoid problems.
Q. I need more help with the battery I bought?
A. Please contact us using the information below.
Contact Us
:
Bioenno Power
:
3657
W. McFadden Ave.
Phone
: +1 888 336-7864
Santa Ana, California 92704
Warranty
Please see the included warranty pamphlet for warranty information. You can also check
for more information.
Bioenno Power
BLF-2440A
LiFePO4 Battery
User Manual