MC-880 System Series

Installation, Operation  

and Maintenance Guide

Содержание MC-880 Series

Страница 1: ...to provide indoor comfort protect occupants and ensure the reliability of critical systems and processes Bioclimatic com 265 AUG 2021 IMPORTANT Save this Document for Future Reference Warranty Inform...

Страница 2: ...installation Follow each installation or repair step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay close attention to all warning...

Страница 3: ...8 2 1 Unit Location 8 2 2 Unit Installation 8 2 3 Electrical Connections 9 2 4 Filter Installation 9 03 PHYSICAL DESCRIPTION 10 3 1 Principle of Operation 10 3 2 Remote Control 11 3 3 Filter Change In...

Страница 4: ...om 05 OPERATION MAINTENANCE 13 5 1 General 13 5 2 Standard Control 14 5 3 Remote Control Option 14 5 4 Multiple Remote Control 14 5 5 Building Management System Control BMSC 14 5 6 Filter Change Light...

Страница 5: ...ent should be thoroughly inspected when received Although all units are properly packaged rough handling in transit can cause breakage Any shortage or damage should be reported at once to the transpor...

Страница 6: ...s leads and finished surfaces from moisture and contamination Do not store unit outdoors Do not store any other material on top of equipment Periodic inspections of the equipment should be made until...

Страница 7: ...owever caused This warranty will not apply if the seller s equipment has been damaged due to improper installation alteration abuse or misuse accident fire flood or unavoidable circumstance Further th...

Страница 8: ...positioned toward the nearest wall The three way supply grille should then be aligned so that air is directed at the farthest point in the room While the noise level generated by the MC 880 is accept...

Страница 9: ...240 volts 1 phase 50 60 Hz the high low setting will adjust only ionization levels The blower for 220 240 volt systems operates at one speed only Power is provided to the unit by means of a three pron...

Страница 10: ...oming into contact with the media pack as it is fragile and can be damaged easily Chemical Media Filter The chemical media or gas phase filter is installed in the same way as the prefilters Do not rem...

Страница 11: ...rs Prefilter static pressure Final Filter static pressure Motor Ionization System High Motor Ionization System Low Local BMS Control Ion generator fault alarm All of the operating controls and visual...

Страница 12: ...ch MC 880 has two pressure control switches mounted inside the of the air handling unit These devises sense static pressure across both filter sections They are individually adjusted at the factory to...

Страница 13: ...of the system After checking that all filters are in place input electrical power is correct and all electrical connections are as per the National and Local codes energize the unit The current being...

Страница 14: ...N Low motor speed ionization level Push button Set third time No lights Unit OFF 3 Push momentarily each of the three buttons marked Test when unit is ON This will cause the visual indicators marked A...

Страница 15: ...ifferential which illuminates the filter change light as follows 1 Remove the hole plug in the top of the unit for access to the adjustment screw 2 With clean filters turn the unit on cover approximat...

Страница 16: ...r to be analyzed as For Test and mark the job name location and unit model number on the plastic bag recommend sing the bag that comes with the replacement filter 2 This bag should be sealed to preven...

Страница 17: ...Installation Operation Maintenance Guide MC 880 System Series 17 1 800 394 3458 265 AUG 2021 Bioclimatic com 06 APPENDICES...

Страница 18: ...Installation Operation Maintenance Guide MC 880 System Series 18 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 19: ...Installation Operation Maintenance Guide MC 880 System Series 19 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 20: ...Installation Operation Maintenance Guide MC 880 System Series 20 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 21: ...Installation Operation Maintenance Guide MC 880 System Series 21 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 22: ...Installation Operation Maintenance Guide MC 880 System Series 22 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 23: ...Installation Operation Maintenance Guide MC 880 System Series 23 1 800 394 3458 265 AUG 2021 Bioclimatic com...

Страница 24: ...24 1 800 394 3458 265 AUG 2021 Bioclimatic com 07 PRODUCT NUMBERS MC 880 MC8809 MC8809 NR MC8809 UV If your specific model is not listed please contact the factory at 1 800 394 3458 for operating ins...