MAINTENANCE
Any operation on the device must be carried out by qualified and
skilled personal.
The device must be disconnected from the electrical network
before any intervention.
Please cut off main power supply with breaker that protect your
equipment.
The handling of UV lamps and quartz sleeves must absolutely be done with
protective
gloves
to avoid leaving fingerprints which could affect the quality of UV emissions and
to protect the hands in the event of glass breakage.
L.1. Lamp replacement procedure
The ultraviolet lamps are designed to last for 13,000 hours, i.e. approximately 3 years for a seasonal outdoor pool,
or 1 year and a half for an indoor pool operating 24 hours a day.
In order to prevent premature wear, it is recommended that they be switched on (i.e. 1 filtration cycle) only once a
day which will also preserve the filtration pump.
1.
The sterilizer MUST be POWERED OFF.
2.
Unscrew the 4 screws of the cover by using a Phillips screwdriver then
remove the cover.
3.
Dismount the connector.