background image

Therapeutic Infrared Heat

 

.

 

  .

I

 

O

 S 

M

 

A

 

R

 

T

®

Save these 

Instructions

Includes:

Product information

Thermostat options

Installation guidelines

Operating Instructions

Technical Specifications

Warranty & Service instructions

Installation and Operator’s Manual

Therapeutic infrared heating systems

for a green, healthy environment

BioSmart

®

 In-Wall Far Infrared Heaters. 

Feel the Difference.

BioSmart 

Technologies

In-Wall Series

Bio-1000F
Bio-1200F

Содержание Bio-1200F

Страница 1: ...tallation guidelines Operating Instructions Technical Specifications Warranty Service instructions Installation and Operator s Manual Therapeutic infrared heating systems for a green healthy environment BioSmart In Wall Far Infrared Heaters Feel the Difference BioSmart Technologies In Wall Series Bio 1000F Bio 1200F ...

Страница 2: ...ion 3 Thermostat Location and Requirements 3 Thermostat Options 3 Section 5 Mounting Instructions 4 New Construction 4 Retrofit Installations 4 Wiring Instructions 5 Section 6 Operating Instructions 5 Section 7 Maintenance Requirements 5 Section 8 Diagnostic Information 5 Troubleshooting 6 Component Diagram 7 Component Listings 7 Schematic 8 Section 9 Technical Specifications 8 Section 10 Warranty...

Страница 3: ... absorbed rapidly by organic materials especially water Since the human body is composed mostly of water a room heated with infrared heat of this specific wavelength will appear to be warmer than the same room at the same temperature warmed by radiant heat of a different wavelength It works so well that infrared in this specific wavelength is used for all medical therapies and devices In medical a...

Страница 4: ... the unit as this may block airflow and cause the heater to malfunction DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or damage the heater Heater has hot parts inside DO NOT use it in areas where gasoline paint or flammable liquids are used or stored Do not block air intakes or exhaust in any manner Use this heater only as de...

Страница 5: ...solid state relay The relay is triggered by completing a millivolt signal that is generated through the heaters control board Closing the millivolt circuit can be accomplished in any number of ways including The use of a simple millivolt thermostat The use of a programmable millivolt thermostat The use of any 24 volt HVAC thermostat A 24 volt BioSmart conversion module is required and is installed...

Страница 6: ...o be used the heater is installed before the sheetrock is applied to the wall See diagram below for proper measurements The mounting studs should be thirteen 13 inches apart Retrofit Installations If this is a retrofit installation the cut out for the installation should be between two wall joists and should measure 13 W 16 H The retrofit brackets will require 4 butterfly screws or similar to hold...

Страница 7: ... thermostat settings that control its operation Your thermostat settings will determine your comfort levels and energy savings Be sure to familiarize yourself with your thermostats operations and features in order to get the most advantage from your infrared heaters technology Section 7 Maintenance Requirements It is important that the intake grill is periodically vacuumed off to prevent dust from...

Страница 8: ...the ceramic plates before putting the heater in service during the fall season B If the burning smell persists the unit must be opened up to determine the cause Possible causes are overheating of the 24 volt thermostat module on systems that are so equipped Another possibility is a faulty high limit switch that shorts to ground but this also causes the heater to automatically shut down The heater ...

Страница 9: ...t Listings 1 Cover 2 Grill 3 Heat Chamber Assembly 4 Ceramic Element 5 Left Insulation Plate 6 Ceramic Terminal Block 7 Top Insulation Plate 8 Case 9 Right Insulation Plate 10 Electronics Mounting Plate 11 Bottom Cover 12 Fans 13 Intake Baffle 14 Fan Assembly 15 High Limit Cover 16 High Limit Switch ...

Страница 10: ...anufacturer s specifications Internal Ceramic Blanket Provides R 45 insulation between the wall and the heater The heater cabinet remains cool to the touch while delivering warm 105 C far infrared heat into the room Life Expectancy 25 Years Thermostat Type Any standard digital programmable or smart thermostat is compatible Safety Cut Off High limit switch with manual reset prevents damage to the u...

Страница 11: ...purpose are expressly limited to the duration of the warranty set forth above Some jurisdictions do not allow limitations on the length of the implied warranty so the above limitation may not apply to you In no event shall BioSmart be liable for any incidental or consequential damages loss of profit or medical expenses caused by any defect failure misuse or malfunction of the product Some jurisdic...

Страница 12: ... Road Suite 1 Yelm Washington 98597 Customer Warranty Service 800 595 9605 North American Distribution and Sales BioSmart Far Infrared Heaters Green Technology for a Modern World www BioSmartSolutions com Warranty Registration No Dealer Installer Information ME3 ...

Отзывы: