Ordering Information

Catalog # 

Description

700-7000 

 Experion System

, 100–240 V, for protein analysis, 

includes electrophoresis station, priming station, 
software, USB2 cable, instructions (analysis kits sold 
separately)

700-7101 

 

Experion Pro260 Analysis Kit for 10 Chips

includes 10 Pro260 chips, Experion Pro260 reagents 
and supplies for 10 chips

700-7102 

 

Experion Pro260 Analysis Kit for 25 Chips

includes 25 Pro260 chips, Experion Pro260 reagents 
and supplies for 25 chips

701-7000 

 

Experion System

, 100–240 V, for protein analysis 

(700-7000), Experion Pro260 starter kit (700-7110)

Catalog # 

Description

700-7110 

Experion Pro260 Starter Kit

700-7151 

Experion Pro260 Chips

, 10

700-7152 

 

Experion Pro260 Reagents and Supplies

, for 10 

chips, includes 3 x 520 µl Pro260 gel, 45 µl Pro260 
stain, 60 µl Pro260 ladder (10–260 kD), 400 µl 
Pro260 sample buffer, 3 spin filters

700-7251 

Experion Cleaning Chips

, 10

700-7254 

Experion Spin Filters

, 10

163-2091 

ReadyPrep

 Proteomics Grade Water

, 500 ml

161-0610 

Dithiothreitol (DTT) reducing agent

, 1g 

161-0710 

2-Mercaptoethanol

, 25 ml 

700-7256 

Experion Pro260 Ladder

LabChip and the LabChip logo are trademarks of Caliper Life Sciences, Inc. Bio-Rad Laboratories, Inc. is licensed by Caliper Life Sciences, 
Inc. to sell products using the LabChip technology for research use only. These products are licensed under U.S. Patent Nos. 5,863,753, 
5,658,751, 5,436,134, and 5,582,977, and pending patent applications, and related foreign patents, for internal research and development 
use only in detecting, quantitating, and sizing macromolecules, in combination with microfluidics, where internal research and development 

use expressly excludes the use of this product for providing medical, diagnostic, or any other testing, analysis, or screening services, or providing 
clinical information or clinical analysis, in any event in return for compensation by an unrelated party.

Experion

 Pro260 Analysis Kit

Quick Guide

Essential Practices

n

  Always wear gloves when handling reagents and chips

n

  Handle chips by the edges; do not touch the glass

n

  Remove chip from packaging only immediately before use

n

  Avoid sources of dust and contaminants when preparing samples and loading the chip.  

  Foreign particles in reagents, samples, and the wells of the chip can interfere with results

n

  Deep-clean the electrodes if contamination is suspected or if a chip was left in the  

  instrument overnight

n

  Use of colored or coated (for example, siliconized polypropylene) tubes when preparing kit  

  reagents or samples is not recommended; such tubes may cause artifacts during the separation

n

  Refer to the instruction manual for more details

DNA

1K = C3

12K = C1

LOT# JM27UP02

EXP APR/25/08

LOT# JJ29UK01

EXP MAR/31/08

LOT# KA31UK01

EXP MAY/01/08

LOT# JJ05UK02

EXP DEC/05/07

Storage Conditions

Product 

Storage

Pro260 chips 

Room temperature

Pro260 reagents 

4

o

C (protected from light)

Life Science 

Group 

07-0195    1009    Sig 0308

10004490     Rev C

Bio-Rad  

Laboratories, Inc. 

Web site 

www.bio-rad.com  

USA 

800 4BIORAD  

Australia 

61 02 9914 2800  

Austria 

01 877 89 01  

Belgium 

09 385 55 11  

Brazil 

55 21 3237 9400  

Canada 

905 364 3435  

China 

86 21 6426 0808  

Czech Republic 

420 241 430 532  

Denmark 

44 52 10 00  

Finland 

09 804 22 00  

France 

01 47 95 69 65  

Germany 

089 318 84 0 

 Greece 

30 210 777 4396  

Hong Kong 

852 2789 3300  

Hungary 

36 1 455 8800  

India 

91 124 4029300  

Israel 

03 963 6050  

Italy 

39 02 216091  

Japan 

03 6361 7000  

Korea 

82 2 3473 4460  

Mexico 

52 555 488 7670  

The Netherlands 

0318 540666  

New Zealand 

0508 805 500  

Norway 

23 38 41 30  

Poland 

48 22 331 99 99  

Portugal 

351 21 472 7700  

Russia 

7 495 721 14 04  

Singapore 

65 6415 3188  

South Africa

 27 861 246 723 

 

Spain 

34 91 590 5200  

Sweden 

08 555 12700  

Switzerland 

061 717 95 55  

Taiwan 

886 2 2578 7189 

 United Kingdom 

020 8328 2000

07-0195_ExperionPro260_QckGde_FINAL.indd   1-2

10/15/09   3:45:25 PM

Отзывы: