5
GENERAL NOTES
1.
GENERAL
The treatment system is complete with all needed equipment as shown on the drawings and specified therein.
The following equipment is provided by BioMicrobics, Inc. with purchase of the system: (a) the FAST® system
sub-assembly, (b) either the foot top and foot bottom or lid, (c) the blower assembly, and (d) blower controls
and alarms. All other items needed for installation and operation are not included.
The contractor will install the FAST® treatment system as manufactured by BioMicrobics, Inc. The contractor will
ensure the proper fabrication of the tank, coordinate between the tank suppliers and FAST® system suppliers,
arrange delivery to the job site, and oversee the installation of the FAST® unit. The tank must provide adequate
pump-out access and must conform to local, state, and all other applicable codes. The tank must also be level
within ±1/2 in [12 mm].
2.
MEDIA
The FAST® media is made of rigid PVC, polyethylene, or polypropylene, and it is supported by the
polyethylene insert. The media will be fixed in position and contain no moving or wearing parts, and it
will not corrode. The media has been designed, and will be installed, to ensure that sloughed solids
descend through the media to the bottom of the septic tank for easy cleanout.
3.
REMOTE MOUNTED BLOWER
The blower must be set in a dry, stable place, and its elevation must be higher than the normal flood
level. A two-piece, rectangular housing is included with the unit. The discharge air line from the blower
to the FAST® system is not included and must be provided and installed by the contractor.
4.
ELECTRICAL
The electrical source should be within 150 ft [45 m] of the blower; consult local codes for longer wiring
distances. Wiring distances must prevent significant voltage loss. All wiring must conform to all
applicable codes (IEC, NEC, etc.). All conduit and wiring must be supplied by the contractor.
5.
CONTROLS
The control panel, which provides power to the blower, comes with an alarm system consisting of a
visual and audible alarm that will indicate blower circuit failure and high motor load. The control panel
is equipped with an SFR® (Sequencing Fixed Reactor) timed control feature. A manual silence button is
included.
6. INSTALLATION AND OPERATING INSTRUCTIONS
Written instructions for proper installation, use, and service of the FAST® system (manuals) are
included with the product and are available online at the BioMicrobics website. Installation of the
FAST® system must be carried out in accordance with the written instructions provided in the
Installation Manual. Moreover, all work related to the installation must be done in accordance with
local codes and regulations.