12
Blower Filter Installation
1.
Make sure the circuit breaker in the control panel is in the OFF position.
Electrical Hazard: Disconnect power before servicing. Failure to do so may result in electrical
shock causing severe bodily injury or death.
2.
Make sure filter base is clean of any particles or dirt.
3.
Install filter onto base.
4.
Install filter assembly cover and secure with the wing nut removed during the removal procedure.
5.
Follow steps 9 and 10 of
Blower Installation
procedure.
CONTROL PANEL REPLACEMENT
Always have all utility lines and equipment marked by a locating service prior to performing any work.
All electrical work shall be properly performed by a qualified electrician per all applicable codes. Failure to do so may
result in severe bodily injury or death.
When replacing a panel, follow the steps below. If relocating the panel, run the electrical supply conduit from the control
panel to the blower location.
Note:
The electrical supply line should NOT exceed 150 ft [45 m] total.
1.
Turn all Power OFF.
2.
Examine wiring directions inside the supplied FAST® control panel (also found at the end of this manual).
3.
A dedicated breaker is required in the building’s master electrical panel. Make connections between the
master panel and FAST® control panel.
4.
Make connections between the blower and FAST® control panel per the electrical diagram.