BLOWER REPLACEMENT 

 

 

All electrical work must be properly performed by a qualified electrician per all applicable codes. 

 

 

Always keep tank openings covered during storage and installation. 

When replacing a blower follow the steps below. If relocating the blower, run the electrical supply conduit from the control 

panel to the desired blower location. Airline piping from the blower to the FAST® unit may NOT exceed 100 ft [30.5 m] in 

total length and must have no more than four elbows. The blower and blower housing must be mounted on a solid base 

such as concrete to avoid settling. 

 

Blower Removal 

1.

 

Remove power from the blower assembly by switching the circuit breaker in the control panel to the OFF position. 

Also, switch off the circuit breaker in the building’s main service panel. If you plan to keep the blower disconnected 

for more than 48 hours, it may be necessary to prevent the discharge of wastewater into the drain field.  

 

 

 

 

Electrical Hazard: Disconnect power before servicing. Failure to do so may result in electrical 

shock causing severe bodily injury or death. 

 

 

2.

 

Remove blower housing cover by unscrewing the mounting bolts and lifting the lid off the blower housing base.  

3.

 

Remove the motor conduit box cover on the blower motor by unscrewing the two screws securing it to the 

conduit box.  

4.

 

Check with an appropriate measuring device to determine if there is power at the electrical wire leads in the 

conduit box before proceeding.  

5.

 

If there is no power at the wire leads, disconnect the power leads from the motor leads, noting the connections 

for proper re-connection during installation. Insulate and support the wires out of the way of the blower so they 

won’t interfere with the blower removal process.  

6.

 

Disconnect the outlet piping of the blower either by disconnecting the union (if used), unscrewing the pipe from 

the blower, or cutting a section of the outlet piping. If the piping needs to be cut, be sure to cut the pipe in an 

area such that a coupling or union (preferred) can be installed at the cut when the blower is re-installed.  

7.

 

Cover the openings in the pipe where the separation occurred to prevent any foreign material from entering. 

8.

 

Remove the mounting bolts securing the blower flange to the blower housing base.  

9.

 

Lift the blower assembly off the blower housing base.  

 

Содержание HighStrengthFAST 1.0

Страница 1: ...ervice Manual For use with MicroFAST 0 5 0 625 0 75 0 9 1 5 3 0 4 5 9 0 MyFAST 1 0 HighStrengthFAST 1 0 1 5 3 0 4 5 9 0 NitriFAST 0 5 0 625 0 75 0 9 1 5 3 0 4 5 9 0 Service Manual FASTSM 001 REV 30 JU...

Страница 2: ...2...

Страница 3: ...SLUDGE DEPTH 8 TANK PUMPING PROCEDURE 9 SEASONAL INTERMITTENT USE 9 BLOWER REPLACEMENT 10 Blower Removal 10 Blower Installation 11 CLEANING THE BLOWER FILTER 11 Blower Filter Removal 11 Blower Filter...

Страница 4: ...ulate in the bottom of the tank for periodic removal The FAST assembly consists of two components the treatment module and blower The blower provides air to the system via the air supply pipe The air...

Страница 5: ...he septic tank for easy cleanout 3 REMOTE MOUNTED BLOWER The blower must be set in a dry stable place and its elevation must be higher than the normal flood level A two piece rectangular housing is in...

Страница 6: ...NSTALLATION OPTION LID INSTALLATION OPTION Only available for model sizes 0 5 through 3 0 on all FAST systems NOTE These images show equipment that is not supplied by BioMicrobics See Installation Man...

Страница 7: ...amaging substances into the FAST system may void the warranty For list of prohibited or limited use substances see the Owner s Manual NORMAL OPERATING CONDITIONS SOUND The FAST system s blower makes a...

Страница 8: ...bris Clean by using built in plunger WATER QUALITY Effluent should be clear and odorless All FAST systems are capable of exceeding the USEPA standard for secondary wastewater treatment 40CFR part 133...

Страница 9: ...solids so they can be effectively pumped out of the tank 4 Once the unit has been pumped out immediately refill the tank with clean water to reduce the risk of the tank floating and to minimize the i...

Страница 10: ...odily injury or death 2 Remove blower housing cover by unscrewing the mounting bolts and lifting the lid off the blower housing base 3 Remove the motor conduit box cover on the blower motor by unscrew...

Страница 11: ...ower using the correct scheme as noted on the inside of the motor conduit box cover 7 Insulate the wires and fit them inside the conduit box in a professional manner 8 Attach the conduit box cover to...

Страница 12: ...ng service prior to performing any work All electrical work shall be properly performed by a qualified electrician per all applicable codes Failure to do so may result in severe bodily injury or death...

Страница 13: ...n FAST tank The FAST tank is flooded Determine cause of flooding e g line obstruction lateral field pump failure high flows etc Blower motor is making a loud whining or grinding noise Blower motor bea...

Страница 14: ...of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty shall be borne by the owner This warranty does not cover...

Страница 15: ...ial Number ________________________ System Designer Name _____________________________ Designer Phone ___________________________________ Installed By ______________________________________ Installer...

Страница 16: ...nother bottle C Dissolved oxygen DO and pH meters may be used If you use them they must be calibrated at the site using the manufacturer s required techniques D A sludge measurement device such as a S...

Страница 17: ...es place the collection container into the stream of effluent and rinse any collection containers including sample bottles that will contain effluent DO NOT rinse TKN and ammonia sample bottles that c...

Страница 18: ...ture in the logbook along with the date address and time K Take the sample bottles and place them into the cooler with the wet ice The bottles should be well covered by the ice in order to facilitate...

Отзывы: