Ap pen dix
Trou bles hoo ting
Not every fault or mal functi on is an ac tu al PABX sys tem er ror. Check your in stal la ti on con fi gu ra ti on with the aid of
the fol lo wing sec ti on.
Fault Des crip ti on
Pos si ble Cau se
Fault Re me dy
No dial tone af ter
lif ting hand set.
PABX not con nec ted to po -
wer supp ly pro per ly.
Check 230 V AC out let (for ex am ple by plug ging in a lamp)
Plug-in po wer supp ly unit /
po wer plug not plug ged in
pro per ly
Check con nec ti on bet ween PABX and 230 V AC out let.
Ter mi nal de vi ce de fec ti ve.
Re pla ce ter mi nal de vi ce / Check ter mi nal de vi ce at ot her con nec ti on
Te le pho ne con nec ti on faul -
ted, Faul ty in stal la ti on
Check PABX / jack con nec tions
PABX set tings faul ted, am -
bi gu ous pro gram ming of
PABX sys tem
Un plug and plug the plug-in po wer supp ly unit back in. Re set the PABX
to in iti al sta te.
No in ter nal calls
are re cei ved.
Sta ti on gu ar ding (do not
dis turb) is ac ti ve.
De ac ti va te sta ti on gu ar ding (do not dis turb).
Call for war ding to anot her
num ber ac ti vat ed (spe ci al
di al to ne in hand set).
Can cel call for war ding.
No ex ter nal calls
are re cei ved.
Sa me cau ses and re me dies pos si ble as for »No in co ming in ter nal calls«.
PABX not con nec ted cor -
rect ly to the net work ter mi -
na ti on unit of your net work
ser vi ce pro vi der.
Check the con nec ti on bet ween the PABX and net work ter mi na ti on unit.
MSN is not en te red or as -
sig ned cor rect ly in the
PABX.
Check the PC con fi gu ra ti on for the PABX.
Note: Check to en su re that ISDN con nec ti on is functio ning cor rect ly, and that this con nec ti on has been en -
ab led by your net work ser vi ce pro vi der. Plea se con tact your ser vi ce pro vi der.
No out going, ex -
ter nal calls pos si -
ble.
No aut ho ri za ti on for ex ter -
nal con nec tions.
Check the user set tings in the PC con fi gu ra ti on for the PABX.
No out going, ex -
ter nal calls pos si -
ble.
Call char ge li mit rea ched
(Al lo wan ce ac count).
Check the user set tings in the PC con fi gu ra ti on for the PABX. In crea se
cost li mit, or re set the sum coun ter
Ex ter nal num bers clas si fied
as re stric ted num bers for
call con trol.
Check the set tings for di al ran ges in the PC con fi gu ra ti on for the PABX
No ex ter nal con -
nec tions pos si ble
to some re
mo
te
ter mi nals.
Ex ter nal num bers are gi ven
in the Re stric ted num bers
list for the dia ling re gi on.
Check the set tings for di al ran ges in the PC con fi gu ra ti on for the PABX
Trou bles hoo ting
Ap pen dix
65