In the WAN->ATM->OAM Controlling menu, a list of all monitored OAM flow levels is dis-
played.
13.2.3.1 New
Choose the New button to set up monitoring for other flow levels.
The menu WAN->ATM->OAM Controlling->New consists of the following fields:
Fields in the OAM Flow Configuration menu.
Field
Description
OAM Flow Level
Select the OAM flow level to be monitored.
Possible values:
•
'
: (virtual channel level) The OAM settings are used for the
virtual channel (default value).
•
'
: (virtual path level) The OAM settings are used on the vir-
tual path.
Virtual Channel Con-
nection (VCC)
Only for OAM Flow Level =
'
Select the already configured ATM connection to be monitored
(displayed by the combination of VPI and VCI).
Virtual Path Connec-
tion (VPC)
Only for OAM Flow Level =
'
Select the already configured virtual path connection to be mon-
itored (displayed by the VPI).
Fields in the Loopback menu.
Field
Description
Loopback End-to-End
Select whether you activate the loopback test for the connection
between the endpoints of the VCC or VPC.
The function is enabled with
7+
.
The function is disabled by default.
End-to-End Send Inter-
val
Only if Loopback End-to-End is enabled.
Enter the time in seconds after which a loopback cell is to be
sent.
13 WAN
bintec elmeg GmbH
230
be.IP 4isdn