background image

По вопросам продаж и поддержки обращайтесь:

Архангельск   (8182)63‐90‐72   
Астана   (7172)727‐132   
Белгород   (4722)40‐23‐64   
Брянск   (4832)59‐03‐52   
Владивосток   (423)249‐28‐31   
Волгоград   (844)278‐03‐48   
Вологда   (8172)26‐41‐59   
Воронеж   (473)204‐51‐73   
Екатеринбург   (343)384‐55‐89 
Иваново   (4932)77‐34‐06  
Ижевск   (3412)26‐03‐58   
Казань   (843)206‐01‐48  
Калининград   (4012)72‐03‐81  
Калуга   (4842)92‐23‐67   
Кемерово   (3842)65‐04‐62   
Киров   (8332)68‐02‐04   

Краснодар (861)203‐40‐90
Красноярск   (391)204‐63‐61   
Курск   (4712)77‐13‐04   
Липецк   (4742)52‐20‐81   
Магнитогорск   (3519)55‐03‐13   
Москва   (495)268‐04‐70   
Мурманск   (8152)59‐64‐93   
Набережные Челны   (8552)20‐53‐41
Нижний Новгород   (831)429‐08‐12   
Новокузнецк   (3843)20‐46‐81   
Новосибирск   (383)227‐86‐73   
Орел   (4862)44‐53‐42   
Оренбург   (3532)37‐68‐04   
Пенза   (8412)22‐31‐16  
Пермь   (342)205‐81‐47   
Ростов‐на‐Дону (863)308‐18‐15   

Рязань   (4912)46‐61‐64 
Самара   (846)206‐03‐16   
Санкт‐Петербург   (812)309‐46‐40 
Саратов   (845)249‐38‐78  
Смоленск   (4812)29‐41‐54   
Сочи   (862)225‐72‐31   
Ставрополь   (8652)20‐65‐13   
Тверь   (4822)63‐31‐35  
Томск   (3822)98‐41‐53   
Тула   (4872)74‐02‐29   
Тюмень   (3452)66‐21‐18   
Ульяновск   (8422)24‐23‐59   
Уфа   (347)229‐48‐12   
Челябинск   (351)202‐03‐61   
Череповец   (8202)49‐02‐64   
Ярославль   (4852)69‐52‐93  

Единый адрес: [email protected]      Веб‐сайт: www.binmaster.nt-rt.ru 

Емкостный зонд PROCAP I BinMaster

Содержание PROCAP I

Страница 1: ...04 4742 52 20 81 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 4862 44 53 42 3532 37 68 04 8412 22 31 16 342 205 81 47 863 308 18 15 4912 46 61 64 8...

Страница 2: ...9250290 Rev A PROCAP I Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Price 5 00...

Страница 3: ...eld Wiring 5 3 3 Grounding 6 4 0 FAIL SAFE SELECTION 7 4 1 Description 7 4 2 Fail Safe High 7 4 3 Fail Safe Low 7 5 0 CALIBRATION 8 5 1 Calibration Verification 8 5 2 Calibration Procedure 8 5 3 Sensi...

Страница 4: ...s 10 Amps 250 VAC maximum Fail Safe Switch selectable High or Low level modes Calibration Set when probe is uncovered COARSE adjust single turn potentiometer FINE adjust single turn potentiometer Stat...

Страница 5: ...d the enclosure to an adequate earth ground Observe all terminal and relay contact ratings as called out on the nameplate and in the installation manual Insure that the enclosure cover is in place and...

Страница 6: ...conductive For electrically conductive material in some applications a coated insulated probe may need be used for the unit to effectively sense the material Contact BinMaster if there are any questi...

Страница 7: ...ment grounding conductor as shown in the figure above This unit uses earth ground as a reference for calibration and detecting a covered or uncovered condition Therefore the vessel in which the PROCAP...

Страница 8: ...and will de energize when the probe is covered In this mode a power failure will cause the relay contacts to indicate that the probe is covered whether it is or not 4 3 Fail Safe Low Fail Safe Low me...

Страница 9: ...es do not use excessive force when adjusting 1 Turn both the COARSE and FINE potentiometers fully counter clockwise CCW The internal COV ERED indicator light should be OFF 2 Turn the COARSE potentiome...

Страница 10: ...is for applying a time delay on going from a covered indication to an uncovered indication The Delay potentiometer labeled CVR is for applying a time delay on going from an uncovered indication to an...

Страница 11: ...the factory Manufacturer s obligation is limited to the cost of material and labor to repair or replace and does not include trans portation expenses 3 This warranty shall not apply to any product tha...

Страница 12: ...925 0290 Rev A 11 Figure 1 1 When the PROCAP I is used for liquid applications the stainless steel threads must be used to insure a proper seal...

Страница 13: ...925 0290 Rev A 12 Figure 1 2...

Страница 14: ...9250290 Rev A FINE POT COARSE POT FAIL SAFE SWITCH TIME DELAY POT UNCVR CVR FIGURE 2 1...

Страница 15: ...directives and harmonized standards This product if installed operated and maintained as described in this manual will provide a safe and reliable point level control device for bulk solid materials P...

Страница 16: ...g down When installing this level indicator in environments where it is possible for moisture or moist air to enter the enclosure through the electrical conduit the conduit opening should be sealed wi...

Страница 17: ...12 77 13 04 4742 52 20 81 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 4862 44 53 42 3532 37 68 04 8412 22 31 16 342 205 81 47 863 308 18 15 4912 4...

Отзывы: