page 28/39
Entry of the number of confirmation codes for an individual call group:
Step Key
Effect
Yellow
LED
1.
Program call
1x flashing
2.
Program selection: “number of
confirmation code”
1x flashing
3.
e.g.
Selecting the call group
(
, 1, 2 or 3)
1x flashing
4.
Selection of program step confirmed
2x flashing
5.
e.g.
Entry of the number of confirmation code
(1 up to 6)
1x flashing
6.
Programming terminated.
lights up for 1.5 sec
6.7
Limitation of the alerting
In case of failure the connected system could continuously issue alarms (false alarm). To prevent the
TWG 01 in this case from continuously transmitting the alerting, i.e. dialing the programmed phone
numbers, it is possible to limit the effectiveness of the incoming alarms. When a selected number (1 up to
9) of incoming alarms of an alarm zone is reached, the TWG will perform no more dialing for 1 hour.
This is valid for the call groups 1, 2, and 3 (not for the call group
)
Setting “0”: no limitation. factory setting: „3“ (up to 3 alerts are effective).
Possible number: 1 up to 9 effective alerts.
Entering the number of effective alerts:
Step Key
Effect
Yellow
LED
1.
Program call
1x flashing
2.
Program selection: “number of effective
alerts“
1x flashing
3.
Selection of program step confirmed
2x flashing
4.
e.g.
Entry of the number of effective alerts
(1 up to 9) or “0“ (no limitation)
1x flashing
5.
Programming terminated.
lights up for 1.5 sec