MKF+ MKFT (E3.2) 07/2017
page 72/115
16. Options
16.1 Communication software APT-COM™ 3 DataControlSystem (option)
The chamber is regularly equipped with an Ethernet interface (10a) that can connect the BINDER com-
munication software APT-COM™ 3 DataControlSystem can be connected. The MAC Address is indicated
next to the Ethernet interface. The actual temperature and humidity values are given at adjustable inter-
vals. Programming can be performed graphically via PC. Up to 30 chambers with RS 422 interface can
be cross-linked. For further information, please refer to the operating manual of the BINDER communica-
tion software APT-COM™.
16.2 Interface RS 422 (option)
With this option, the chamber is equipped with a serial interface RS 422 (10b) instead of the Ethernet
interface (10a) that can connect the BINDER communication software APT-COM™ 3 DataControlSys-
tem. The actual temperature and humidity values are given at adjustable intervals. For further information,
please refer to the operating manual of the BINDER communication software APT-COM™.
Pin allocation of the RS 422 interface:
Pin 2:
RxD (+)
Pin 3:
TxD (+)
Pin 4:
RxD (-)
Pin 5:
TxD (-)
Pin 7:
Ground
16.3 Analog outputs for temperature and humidity (option)
With this option, the chamber is equipped with analogue outputs 4-20 mA for actual value and set-point
value of temperature and of humidity. These outputs allow transmitting data to external data registration
systems or devices.
The connection “analog outputs for temperature” is realized as a DIN socket (13) in the lateral control
panel as follows:
ANALOG OUTPUT TEMPERATURE 4-20 mA DC
PIN 1: Temperature actual value –
PIN 2: Temperature actual value +
PIN 4: Temperature set-point value –
PIN 5: Temperature set-point value +
MKF:
Temperature range: -40 °C
/ -40°F
up to +180 °C
/ -356°F
MKFT:
Temperature range: -70 °C
/ -94°F
up to +180 °C
/ -356°F
A suitable DIN plug is enclosed.
Figure 20: Pin allocation of DIN socket (13) for option analog outputs for temperature
The connection “analog outputs for humidity” is carried out as a DIN socket (14) in the lateral control pan-
el as following:
ANALOG OUTPUT HUMIDITY 4-20 mA DC
PIN 1: Humidity actual value –
PIN 2: Humidity actual value +
PIN 4: Humidity set-point value –
PIN 5: Humidity set-point value +
Humidity range: 0 % r.H. up to 100 % r.H.
A suitable DIN plug is enclosed.
Figure 21: Pin allocation of DIN socket (14) for option analog outputs for humidity
Содержание MKF 115
Страница 97: ...MKF MKFT E3 2 07 2017 page 97 115 20 10 Dimensions MKF 115 MKFT 115...
Страница 98: ...MKF MKFT E3 2 07 2017 page 98 115 20 11 Dimensions MKF 240...
Страница 99: ...MKF MKFT E3 2 07 2017 page 99 115 20 12 Dimensions MKFT 240...
Страница 100: ...MKF MKFT E3 2 07 2017 page 100 115 20 13 Dimensions MKF 720 MKFT 720...
Страница 102: ...MKF MKFT E3 2 07 2017 page 102 115...
Страница 103: ...MKF MKFT E3 2 07 2017 page 103 115...
Страница 104: ...MKF MKFT E3 2 07 2017 page 104 115 21 2 EU Declaration of Conformity for MKFT...
Страница 105: ...MKF MKFT E3 2 07 2017 page 105 115...
Страница 106: ...MKF MKFT E3 2 07 2017 page 106 115...
Страница 108: ...MKF MKFT E3 2 07 2017 page 108 115...
Страница 109: ...MKF MKFT E3 2 07 2017 page 109 115 22 Product registration...