Страница 2: ...sting Be careful to open the box and check the accessories as follows 1 switch 2 console wire 3 Adaptor If any damage of products or shortage of accessories inside the box please contact the local dis...

Страница 3: ...intimately and conveniently 1 2 Agreement The following sections in this manual all for SW GE1008F switches 1 3 Summary of user manual Chapter 1 Introduction of user manual Chapter 2 Product overview...

Страница 4: ...ndwidth can reach 20Gbps storage and forward architecture Supports up to 16 802 1Q tag based VLAN 8 k MAC address Support address learning of each port Support Port Trunk Support Port Mirror Support b...

Страница 5: ...Cat5 UTP or STP 1000BASE SX Multi mode Fiber 1000BASE LX Multi mode fiber or single mode fiber 1000BASE T Cat5 UTP or STP MAC Address Table 8K Backplane Bandwidth 20G Filtering and forwarding rate 10...

Страница 6: ...achments including but not limited to the power wire etc can only be used for this switch banned for other products The installation way on the table 1 Put the switch directly on the desktop The insta...

Страница 7: ...e operating voltage When normal Power up the switch power indicator in the front panel will turn on Attention When the power supply system failure or temporary power failure to ensure that the switch...

Страница 8: ...ndicator light is green normally on When data transmission the indicator is flashing When the port work in 100Mbps or 1000Mbps full duplex state corresponding to the LED indicator light is green on 2...

Страница 9: ...hielded twisted pair its length is not greater than 100 meters Cat3 or above Cat3 UTP for 10Base T Ethernet Cat5 or above Cat5 UTP for 100Base T Ethernet Cat5 or Cat6 UTP or above for 1000Base T Ether...

Страница 10: ...utomatically by DHCP Default state of the DHCP function is closed it can be configured manually switch IP address and subnet mask and default gateway under the closed position DHCP function should be...

Страница 11: ...an transmit outward PAUSE frame at this time the equipment which received the frame will stop for a period of time to send operation according to PAUSE frame data the inactive time is measured in Quan...

Страница 12: ...tandard after the founding the equipment of different manufacturers can use in a network at the same time the switch which support IEEE802 1Q can communicate with other switches IEEE802 1Q defines a n...

Страница 13: ...echnology these ports can be view as a port After setting Trunk the switch from the outside and the Trunk and Trunk ports in a VLAN other port load automatically assigned to the various ports in the T...

Страница 14: ...the frame transmission level high level of frame will be priority Classification can be set based on the priority of port priority and DSCP priority 802 1 p The user can select the current priority cl...

Страница 15: ...TFTP Server to update the switches file download the files provided by the TFTP Server to switch so as to realize the upgrade and update of switching software At the same time through the file upload...

Страница 16: ...g Picture 5 6 Enter dialogue diagram In the specified password input box to enter the password the default password is admin click the submit button switch into the WEB management page Note The defaul...

Страница 17: ...17 Picture 5 7 The SW GE1008F WEB home page Picture 5 8 Function Menu As shown in 5 8 the left side of the function menu is a list the menu is divided into two layers the main...

Страница 18: ...configuration port configuration 802 1 Q VLANS configuration RSTP port trunking port mirror configuration port isolation broadcast storm control self loop detection quality of service configuration S...

Страница 19: ...switch managed port s VLAN ID are the same with the managed VLAN ID that switch can be managed Switch s name identify of switch in the network Password login password The Web s largest idle time Set W...

Страница 20: ...er or not when in congestion setting package processing Start 802 3az standard open the energy saving mode VLAN configuration VLAN configuration 802 1 Q VLANs configuration Basic knowledge about VLAN...

Страница 21: ...when port receives tagged packets if does not hook on using port forwarding belonging to the VLAN ID ALL The port can receive tagged packets and untagged packets Tagged The port can only receive tagg...

Страница 22: ...green on the Trunk click the ok button to set Trunk configuration rules 1 SW GE1008F switches support up to eight Trunk Trunk can be no more than 10 members 2 Has become a member of the Trunk port ca...

Страница 23: ...system Hello Time Hello time interval Max Age The largest aging time Forward Delay Forwarding delay Force version The protocol version of communication setting Port configuration Enable protocol turn...

Страница 24: ...Router Ports Set up the router port request message to allow input from the router port IP multicast setting To allow multicast flooding whether or not In view of the VLAN IGMP Settings Configure IGMP...

Страница 25: ...e port to get monitoring information instructions Group of Trunk member ports cannot be serve monitor but can be monitored as port The monitoring ports and the ports be monitored in the same VLAN A po...

Страница 26: ...st storm control Picture 5 17 Broadcast storm control configuration The user can through this page to control the broadcast storm Set forwarding rate of IGMP the study frame rate the broadcast packet...

Страница 27: ...oad detection and prevention And a cross between Loop Detect and RTSP can prevent the network loop Quality of service configuration Quality of service configuration includes QoS Disabled 802 1P DSCP P...

Страница 28: ...ity queue Custom all low Priority all Normal Priority all Medium Priority all high priority 802 1P Value For the tagged in three priority value of 802 1 Q packets vand the range of 0 7 The port priori...

Страница 29: ...ta message Priority The priority option of DSCP values 5 3 2The system status monitoring The port statistical information Picture 5 22 All the statistical information web content of port Picture 5 22...

Страница 30: ...30 RSTP status Picture 5 23 All ports status of RSTP Upgrade update information in real time IGMP State Picture 5 24 IGMP status Upgrade update information in real time...

Страница 31: ...31 Loop detect Status Picture 5 25 All ports status of Loop detect Upgrade update information in real time Ping Picture 5 26 Ping status...

Страница 32: ...real time 5 3 3 System maintenance System Warm Restart Click on the system warm restart options and the menu pop up dialog as follows Picture 5 23 Warm Restart setting tooltip Click yes to start warm...

Страница 33: ...upload button the file will be uploaded to the device after the completion of the upload it will restart Configuration Upload Picture 5 26 Configuration upload and download web page content Configurat...

Страница 34: ...e switch and the computer the rear panel of the far right and then run HyperTerminal How to configure Hyper Terminal As below Picture 6 1HyperTerminal configuration You can see that the serial port s...

Страница 35: ...mand please enter the front part of this command and then type Or space Command line prompt a list of possible commands section of the remaining part of the command line So that you can continue to en...

Страница 36: ...Default keep IP Parameter Description keep IP When restoring the switch to keep the switch to factory defaults does not change the IP Features Description Restore the switch to factory defaults Comma...

Страница 37: ...lue is 60 10000 Features Description Display or change the idle time of the console Command Format Console Password password Parameter Description password Switch s password is string If it is then se...

Страница 38: ...nable is turned on disable is turned off Features Description Turn on off link of physical port Command Format Port Max Frame portlist framesize reset Parameter Description portlist Physical switch po...

Страница 39: ...Command Format MAC Lookup macaddress vid Parameter Description macaddress MAC addresses can be expressed as 010203ABCDEF or 01 02 03 AB CD EF or 01 02 03 AB CD EF vid VLAN ID Features Description Find...

Страница 40: ...d with a tag from a data frame Features Description Set the switch receives the VLAN tagged packets without a tag If you choose all that receive all the packets if you choose tagged that receive only...

Страница 41: ...e Port VLAN Configuration Command Format User Group Configuration Features Description Display all port based VLAN information Command Format User Group Add grouplist portlist Parameter Description gr...

Страница 42: ...h port list enter the form can be 1 3 or 1 3 5 8 default for all physical ports tagpriolist vlan User Priority 0 7 class Service levels have low normal medium or high Features Description Display and...

Страница 43: ...l ports enable is turned on and disable is turned off Features Description Set the multicast packet rate limit granularity of 250Kbit s Port mirror setup command Command Format Mirror Configuration Fe...

Страница 44: ...e ping w timeout connect computers ping time Established IP address of the switch ipaddress Features Description Detect a switch connected to the computer by ping command Command Format IP Arp Feature...