16
3.4 Installation of LPG Gas - Recommendations and Care
Verify that the location where the equipment will be installed is aired and in accordance with
the Regulations for the Prevention of Risks at Work and Safety at Work in Machinery and Equipment
(Regulatory standard NR-12 for Brazil or according to the regulatory standard in force in your
country), and periodic inspections of a technician are recommended to ensure that its components
are in good condition.
CAUTION!
Even with a safety system (which cuts off the gas in case the flame of a burner goes out), the
equipment should be arranged in an airy place, but without airflow, thus preventing the flames
from being burned in the burners, causing possible gas leakage.
The gas installation should be carried out by a qualified technician for this function and
observing the safety regulations.
A kit for low pressure gas installation is supplied with the equipment. The kit has a pressure
regulator (Gas canister
0.7/7.0 kgf/cm² - Regulator (FTG.150) 6,4 kPa e (FTG.300) 13.2 kPa
– Flow
rate 4 kg/h), a hose with connection for two gas valves to be fixed in two gas cylinders P13.
IMPORTANT
The natural gas kit is an optional item and does not accompany the pressure regulator and
hose connection. The installation must be direct to the gas inlet valve.
The kit should be installed with the following recommendations:
•
Gas canister
- 02 cylinders with a minimum mass of 13 kg (code P13) of LPG (liquefied
petroleum gas) will be required for this equipment. The cylinders must comply with the ABNT 8460
standard for Brazil or according to the regulation in force in your country. Check the product
warranty seal. If you have violated, do not install.
CAUTION!
Never install only a single gas canister, freezing may occur with this canister.
For gas installation code P45, please contact your local gas installation company in your city.
•
Hose
- Screw the end that does not have the gas valve into the gas inlet valve, located on the
right side of the front shield. The hose must not cross or be embedded in walls, and should not
make any kind of seam (welding or gluing). Never use wires or tapes.
•
Gas Regulator and Pressure Regulator
- In the kit there is a pressure regulator and two gas valves.
When installing the valves in the cylinders, turn the butterfly nipple clockwise until it is firm. Never
use tools to perform this operation. Valves should remain closed whenever the gas is not being
used.
Содержание Metvisa FTG.150B
Страница 1: ......
Страница 10: ...10 Follow the guidelines below to assemble the stand ...
Страница 30: ...30 9 ANNEXES Electrical Schematic Voltage 110 V or 127 V 60 Hz NOTE FTG150 oven uses only one Door Light ...
Страница 31: ...31 Explosion Design ...
Страница 32: ...32 Explosion Design ...
Страница 33: ...33 Explosion Design ...
Страница 34: ...34 Explosion Design ...
Страница 35: ...35 Explosion Design ...
Страница 43: ...43 ...