V5 Lubricator Assemblies
Automatic Continuous
Operation
The V5 Lubricator assemblies consist of a reservoir, low level switch, motor-driven gear pump, and
threaded return port or return filter. Pump also includes a built-in flow bypass valve. (Constant
volume) The fully automatic lubricating system is preset to max discharge from the factory.
Discharge volume may be adjusted by turning the bypass valve counter-clockwise to reduce.
Technical Data
SINGL
E PHASE
Motor Type
72123/72124/72125/
72125-RF
CONTINUOUS DUTY, T.E.N.V.
72126/72126-RF
CONTINUOUS DUTY, T.E.F.C.
Motor Voltage
115 VAC
1/20 hp, NEMA Frame L330, continuous duty
Frequency
60/50 Hz
Speed
1725/1425 rpm (60/50Hz)
Start Amperage
2.3/2.5 amp
Run Amperage
0.78/0.67 amp (60/50Hz)
Maximum Ambient Temperature
104°F (40°C)
Pump Discharge
132cc/min (110cc/min 50 Hz)
Pump Inlet filter
125 Micron
Relief Valve
130 psi
THREE PHASE
Motor Type
72127/72127-RF
CONTINUOUS DUTY, T.E.F.C.
Motor Voltage
230-240/400-415 VAC 50 Hz
0.10 / 0.08 hp 60/50 Hz
260-280/440-480VAC 60 Hz
Frequency
60/50 Hz
Speed
1480/1230 rpm 60/50 Hz
Maximum Ambient Temperature
104°F (40°C)
Pump Discharge
120cc/min (100cc/min 50 Hz)
Pump Inlet filter
125 Micron
Relief Valve
200 psi
Discharge Adjustment
The V5 Lubricator is fitted with a flow bypass valve(Constant volume). Pressure is limited internally to
130 psi by a relief valve (Some models limited to 200 psi). See page 23 for details.
System & Limitations
Use Type C control units. Viscosity range is 20 to 1500 cSt at operating temperature.
See
Bijur Engineering Manual
for system limitations.
Use clean oil only of the type and viscosity
recommended by machine manufacturer.
Replace filter group annually.
V5 72125
Refer to the following data sheets
for available reservoirs:
+
Tech sheet #TS030
V5W Replacements