V5 Lubricator
Automatic Continuous, 60444 Davenport
V5 60444 Lubricator
Use clean oil only of the type and viscosity
recommended by machine manufacturer.
Replace filters annually.
Operation
The V5 Lubricator consists of a motor-driven gear pump with a controlled constant volume discharge.
The fully automatic lubricating system is preset by the machine manufacturer for best operation.
Discharge volume may be adjusted by turning the bypass valve counter-clockwise to reduce the
pressure and thus automatically reduce the amount of oil, or by closing valve to increase pressure
and oil flow.
Technical Data
Single Pha
se Mo
tor
Motor
1/20 hp 50/60 Hz CONTINUOUS DUTY, T.E.F.C.
Voltage
115 VAC
Frequency
60/50 Hz
Speed
1370/1670 rpm 50/60 Hz
Maximum Ambient Temperature
104°F (40°C)
Pump
Outlet Connection
5/16-24 Female for 5/32” O.D. Tube (4mm)
1
Discharge
132cc (110 cc/50Hz)
Bypass Regulation
Flow Bypass
Relief Valve
50 psi
Inlet Filter
60 Micron
Outlet Line Filter
25 Micron
Reservoir
8 Liter
Level Switch
Single Contact N/O
Pressure Switch
SPST N/O
Opens @ 9+/-1 psi on falling pressure
Closes @ 11+1-2psi on rising pressure
Pressure Gauges
0-100 psi
1
Use B1371/B3783 compression bushing with B1061/B8272 sleeve
Discharge Adjustment
The V5 Lubricator is preset with a closed bypass valve for a maximum discharge of 132cc per minute.
With lubricator at normal operating temperature on machine, desired discharge volume is obtained
by adjusting the bypass valve to pre-calculated pressure on system pressure gauge. Pressure is
limited internally to 50 psi by a relief valve.
System & Limitations
Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature.
See
Bijur Engineering Manual
for system limitations.
Notes:
P.N. 60444 Replaced P.N. 32283