SureFire II Lubricator

Quick Start Manual

PDI Operation

The SureFire II PDI Lubricator has a motor-driven pump that
pulls lubricant in from the reservoir and delivers pressurised
lubricant to the distribution network through the outlet(s) in
the top plate. Pressurising the distribution network forces all 
of the positive displacement injectors (PDIs) in the system to 
fi re, discharging the lubricant that was stored in each of their 
discharge chambers during the last pump cycle.

The pressure in the main line continues to rise activating the
pressure switch until relief pressure is reached, at which 
stage, the relief valve opens and discharges the pressurised 
lubricant back into the reservoir. The pressure switch can be 
used to stop the motor, and momentary pressure in the main 
line becomes greater than the pressure at the outlet side of 
the gear pump. This pressure differential actuates a quick 
dump valve which relieves the main line pressure back into 
the reservoir.

SLR Operation

The SureFire II SLR Lubricator has a motor-driven pump that 
pulls oil in from the reservoir and delivers pressurized oil to 
the distribution network through the outlet(s) in the top 
plate. Pressurizing the distribution network forces all of the 
resistance fi ttings in the system to discharge the oil in 
proportioned quantities to the friction points. The resistance 
fi ttings continue to fl ow and the pump builds pressure until 
pressure relief valve setting is reached (75 psi/5 bar). Once 
the motor is shut off, pressure in the distribution network 
returns to near 0 psi via a quick dump valve.

Installation and Commissioning

  

Install the SureFire II Lubricator in the 

horizontal position ONLY. Attach the lubricator in the desired 
location and to the desired equipment by means of an 
appropriately sized bolt through each of the (2) mounting 
holes in the top plate.  (2L & 3L=M6, 6L=M8) The lubricator 
should be installed in a location that is easy to access, for 
purposes of viewing the front panels, for ease of 
reservoir-fi lling, for ease of service and for ease of 
attachment to the distribution network plumbing. 

Remember the SureFire II lubricator allows attachment of 
distribution plumbing to either (or both) sides of the top 
plate. If only one side is used, be sure to plug the unused 
outlet with a G1/4 BSPP plug (two plugs are included with 
each lubricator). 

Two liquid tight fi ttings are supplied with the lubricator. Use 
the liquid tight fi ttings to secure the electrical wiring for the 
lubricator and to prevent ingress of fl uids or dirt getting into 
the motor compartment. Typically one of the fi ttings is used 
to bring “power” into the motor compartment and the other 
fi tting is used to bring “signal” into or out of the motor 
compartment.

All tubing, fl exible hoses and fi ttings must be compatible with 
the lubricant, operating pressure and surrounding 
environment. In general, try to install the lubricator in the 
lowest position (vertically) with relation to the rest of the 

2 Litre Single Phase Standard

3 Litre Single Phase w/ Controller

SAFETY  

 

General safety instructions

 Electrical safety instructions

 Safety instructions which promote safe 

operation of the lubricator

 Electrical connections made to Earth ground are 

identifi ed by this symbol

 Conditions and actions that pose potential 

hazards to the user are marked by this sign

All safety and/or warning labels affi xed to the SureFire II 
lubricator must be maintained in a completely legible condition. 
Also, any modifi cations made to the SureFire II Lubricator 
(or to any of its components) must be approved by BIJUR 
DELIMON prior to its use, otherwise the warranty and any 
liability by BIJUR DELIMON will be null and void.

distribution network and do not allow the tubing to rise and 
fall when avoiding obstacles. This is in case air enters the 
distribution lines, the bubbles will tend to rise towards the 
end of the distribution lines and not get caught anywhere 
along the way. Any air bubbles trapped in the distribution 
network plumbing may prevent the PDI injectors from 
working properly.

       

    All electrical connections are 

to be made by a qualifi ed technician and all local electrical 
codes are to be followed. When electrical connections are 
being made, do so before the power leads are connected and 
before the power is supplied.
Consult the wiring diagram (located under the motor cover) 
for the correct wiring for your SureFire II lubricator.

 

 

    The installation should provide 

a means of disconnecting the power supply for servicing. 
Such means shall allow for switching off the power during 
normal operation and/or in an emergency. Also, a residual 
current device is required to automatically disconnect the 
power supply in the event of a failure in basic insulation. 

This emergency disconnecting switch should be located in 
close proximity to the equipment and within easy reach. The 
switch should be marked as the disconnecting device of the 
equipment and have ON/OFF positions clearly identifi ed. It 
should also meet the requirements of IEC60947-1 or 
IEC60947-3.

Be sure that all plumbing distribution lines are clean, are not 
kinked and are free from any chips or any other impurities.

    Fill the reservoir through the fi ll cap and/or 

fi ll cap strainer with clean lubricant specifi ed by the Original 
Equipment Manufacturer and that meets all of the lubricant 
specifi cations to the right.

 Do not overfi ll the reservoir. Never fi ll past 

the “MAX” level as noted on the reservoir. Overfi lling could 
cause damage to the electrical components located under 
the motor cover.

Pump Priming

Filling the reservoir and turning on the lubricator is usually 
enough to prime the pump. However, in the case of a very 
thick lubricant, sometimes it’s necessary to assist priming 
the pump. Upon initial start-up, if no lubricant is being 
delivered to the pump outlet, make sure the pump is primed.

Avoid all kinds of impurities as dirt particles are the most 
common cause of gear pump failure. If you wish to determine 
whether the lubricant you plan on using is approved for use 
with Bijur Lubricating Systems, you can consult the Customer 
Service Department.

To prime the distribution network, plumb the entire system 
(mainline tubing, manifolds, junctions, air/oil blocks, injectors, 
injector outlet tubing to bearing points, meter units etc.). 
Then, remove a plug or injector at the point furthest away 
from the pump. Now, run the pump until bubble-free lubricant 
fl ows from this point. Replace the plug or last injector.

Lubrication Specifi cations:

Standard Oil version:

20 to 1500 cSt @ operating temperature

Light Oil version:

5-40 cSt @ operating temperature

Grease version (PDI only):

NLGI grade 000 - 00 (40,000 cSt max)

Motor Duty Cycle:

100/115VAC and 200/230VAC motors: S3, 20%, 15 Min. 

This means that the maximum continuous “on time” for 

any cycle is 3 minutes, and if the motor continuous “on 

time” for a cycle is X, the required minimum “off time” 

for that same cycle is at least 4X. Each motor has an 

internal high temperature cut-off switch.

24 VDC motor: S1, Continuous Duty

Содержание SureFire II

Страница 1: ... to the user are marked by this sign All safety and or warning labels affixed to the SureFire II lubricator must be maintained in a completely legible condition Also any modifications made to the SureFire II Lubricator or to any of its components must be approved by BIJUR DELIMON prior to its use otherwise the warranty and any liability by BIJUR DELIMON will be null and void distribution network a...

Страница 2: ...ear Pump Level Switch Momentary Switch Motor On Led System Relief Valve System Dump Valve Controller Assy Component Illustration SureFire II Spare Parts SureFire II Reservoir Size 2 Liter 3 Liter 6 Liter 12 Liter Part Description Part Part Part Part 24VDC Motor Kit includes driveshaft Coupling 71111 2 71111 6 71111 12 115VAC Motor Kit includes driveshaft Coupling 71112 2 71112 6 71112 12 230VAC Mo...

Страница 3: ...Litre 5 261 225 243 50 5 233 5 182 50 215 5 153 5 5 188 184 Ø 7 Ø 7 Ø 9 6 Litre 3 Litre 2 Litre Troubleshooting Premature wear of the gear pump and the other moving parts is usually caused by dirty or contaminated lubricant Failure of the PDI injectors or SLR Meter Units to deliver lubricant can be caused by an incorrect commissioning sequence resulting in either air or dirt being trapped in the d...

Страница 4: ...5 VAC 230 VAC max Single Phase 250cc min at 60 Hz 210cc min at 50 Hz Output Volume 24 VDC max 250cc min Output Pressure max PDI 31 bar SLR 5 bar Motor Voltage Options 100 115 VAC 50 60 Hz Single Phase 200 230 VAC 50 60 Hz Single Phase 24 VDC Motor Power Requirements 100 115 VAC Single Phase 1 0 amps 200 230 VAC Single Phase 0 70 amps 24 VDC 2 4 amps Motor Duty Cycle 100 115 VAC and 200 230 VAC S3 ...

Отзывы: