background image

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

 

(800) 631 0168 

TOLL-FREE    

(919) 465 0516 

FAX   

 

www.bijuRdELimOn.COm

2100 Gateway Centre blvd., Suite 109    
morrisville, nC 27560

24797  •  R3 

10/08

1

L2P Lubricator

manual, One Shot

Operation

The L2P Lubricator is of the spring discharge type. it is operated by pulling the knob which raises a 
piston and compresses a spring. Releasing the knob automatically discharges oil into the system. Oil 
viscosity does not affect discharge volume, but may affect system pressure.  

Technical Data

Reservoir Capacity

200cc

Viscosity range

100 to 10,000 SSu at operating temperature

Lubricator Inlet Filter

40 micron particle separation

Discharge Pressure

30 psi average

Discharge Volume Per Stroke

1 or 2cc, factory set as specified on customer’s order

Notes Regarding Use

The lubricator inlet filter should be inspected periodically and cleaned/replaced as required.

1. 

discharge pressure will decrease as discharge volume decreases and the number of meter units 

2. 

in the system increases.

System & Limitation

use Type F meter units. do not exceed 60 meter units. To calculate system flow (ø), refer to  

Bijur Engineering Manual

.

Maximum Permissible Total System Flow (ø)

Meter Units (#)

CC Per Shot

1

2

5

240

450

10

170

320

15

140

250

20

115

210

25

100

180

30

85

150

40

60

120

50

57

90

60

---

60

Startup Instructions

Fill reservoir with oil.

1. 

Start machine and see that oil flows freely at all bearings.

2. 