L2P Lubricator
manual, One Shot
Operation
The L2P Lubricator is of the spring discharge type. it is operated by pulling the knob which raises a
piston and compresses a spring. Releasing the knob automatically discharges oil into the system. Oil
viscosity does not affect discharge volume, but may affect system pressure.
Technical Data
Reservoir Capacity
200cc
Viscosity range
100 to 10,000 SSu at operating temperature
Lubricator Inlet Filter
40 micron particle separation
Discharge Pressure
30 psi average
Discharge Volume Per Stroke
1 or 2cc, factory set as specified on customer’s order
Notes Regarding Use
The lubricator inlet filter should be inspected periodically and cleaned/replaced as required.
1.
discharge pressure will decrease as discharge volume decreases and the number of meter units
2.
in the system increases.
System & Limitation
use Type F meter units. do not exceed 60 meter units. To calculate system flow (ø), refer to
Bijur Engineering Manual
.
Maximum Permissible Total System Flow (ø)
Meter Units (#)
CC Per Shot
1
2
5
240
450
10
170
320
15
140
250
20
115
210
25
100
180
30
85
150
40
60
120
50
57
90
60
---
60
Startup Instructions
Fill reservoir with oil.
1.
Start machine and see that oil flows freely at all bearings.
2.