background image

4VLM HOSES

Do not sterilize

ENG INSTRUCTIONS FOR USE.

Other languages available on
https://dental.bienair.com/IFU

Rx Only

REF 2100031-0002/2022.09

Содержание 4VLM HOSES

Страница 1: ...4VLM HOSES Do not sterilize ENG INSTRUCTIONS FOR USE Other languages available on https dental bienair com IFU Rx Only REF 2100031 0002 2022 09...

Страница 2: ...31 0002 2022 09 HOSE 4VLM 4VLM11 Bien Air Dental SA Devices HOSE 4VLM11 GREY REF 1600097 001 HOSE 4VLM GREY REF 1600102 001 Optional accessories NUT REF 1300876 010 MAINT SPRAYNET BOX OF 6 CANS REF 16...

Страница 3: ...ecautions for use 6 4 Description 8 4 1 Overview 8 4 2 Assembly and preparation 9 4 2 1 Motor coupling 9 4 2 2 Turbine coupling 10 4 3 Assembly 11 4 4 Technical data 13 4 5 Classification 13 4 6 Perfo...

Страница 4: ...zard that could result in light or moderate injury ordamage to the device if the safety instructions are not correctly followed Authorized EC Representative in the European Community Wearprotective gl...

Страница 5: ...ect age race or cul ture The intended user is responsible to select the adequate device for the pa tient according to the specific clinical application 2 4 Intended user Product intended for professio...

Страница 6: ...requency bands used locally avoid the presence of devices equipped with 5G broad band cellular networks in the clinical environment or ensure that the network functionality of these devices is disable...

Страница 7: ...wires and or the external sheath l It is essential to use dry purified compressed air in the dental unit in order to ensure the long work ing life of the device Maintain the quality of the air and th...

Страница 8: ...e The technical specifications illustrations and dimensions contained in these instructions are given merely as an indication They may not give rise to any claim The original language of those instruc...

Страница 9: ...pushing it forward FIG 2b 2 Check that the rear of the motor and the joint on the hose are clean Position the motor and its proprietary hose as shown in FIG 2c Rotate it to find the ex act position an...

Страница 10: ...Bien Air Dental hose to the nut FIG 4a 2 Push forward the hose with the screwed nut into the turbine coupling FIG 4b 3 Push fully to the stop the turbine into Unifix quick couplings 4 hole instruments...

Страница 11: ...le top device to avoid any traction on the wires and tubes FIG 5b The outer tube must not be wrinkled after installation The resistance to traction is 60N maximum Description FIG 5 1 1 5 2 5 mm green...

Страница 12: ...12 FIG 6 FIG 7 1 The conical piece provided can be useful for connecting the cooling tube to the unit tube FIG 6 FIG 7...

Страница 13: ...1600071 001 for more information 4 5 Classification Class IIa in accordance with the European Medical Regulation EU 2017 745 4 6 Performances No performances related to the hose alone Refer to the IFU...

Страница 14: ...Remove the product residues with a clean cloth soaked either in tap water or in sterile demineralized deionized water 5 4 Drying Spray the exterior of the hose with Spraynet then remove its excess wit...

Страница 15: ...ve humidity range 5 80 Airpressure range 650 hPa 1060 hPa Keep away from rain 6 2 Disposal The disposal of this device must be performed in accordance with the legislation in force This device must be...

Страница 16: ...ance instructions l Damage caused by unusual chemical electrical or electrolytic influences l Faulty air water or electrical connections Are excluded CAUTION The warranty becomes null and void if dama...

Страница 17: ...enne 6 Switzerland Tel 41 0 32 344 64 64 Fax 41 0 32 344 64 91 dental bienair com Other addresses available at www bienair com Bien Air France S rl 19 21 rue du 8 mai 1945 94110Arcueil France REF 2100...