BIDELI BD-06WT/NT Скачать руководство пользователя страница 1

Instruction manual

Model: 

BD-06WT/NT

     Name:6KG Coffee Roaster 

GAS

P1

Содержание BD-06WT/NT

Страница 1: ...Instruction manual Model BD 06WT NT Name 6KG Coffee Roaster GAS P1...

Страница 2: ...on our company will response for repairs of the roster for free Under the circumstances below we don t offer free repair during warranty 1 The damage by fire earthquake flood typhoon lightning other n...

Страница 3: ...C 220V 50 60Hz Outside Dimension 2200 1300 2200mm Roasting Capacity 3 6kg Batch Drum Rotation Speed 55 65 circles 61circles min standard Drum Power 0 37KW Cooling Mix Rate 10 8 circles min Cooling Mix...

Страница 4: ...y information 2 Safety tags 3 Safety device 3 installation 1 transportation 2 Check before installation 3 The installation 4 equipment usage profile 1 General requirements 2 Equipment structure 3 Oper...

Страница 5: ...ich hot to puffed the coffee bean u High thermal efficiency utilized could made deep roaster within 15 minutes as well as keep the inherent taste and aroma uUsing an exhaust valve to control the displ...

Страница 6: ...ing tray damage variants u In the cooling coil mixing process can not put your hand on the position of stirring blade rotation u Within the drum during rotation can not put hand inner of the drum afte...

Страница 7: ...d exists before use 2 Drive parts This label indicates Note Drive site It will occur injuries at the part of drive Please add the safety device when using it and turn on the power switch 3 Caution bur...

Страница 8: ...gas supply Drop by 10 it will automatically resume heating gas type baking opportunity to restore the gas supply and automatic ignition 3 Prevent electric leakage devices u The machine cut off the pow...

Страница 9: ...3 Preparation before installation roaster 1 Equipment Placement u Baking machine placed on the flat ground 2 Exhaust duct u This baking equipment must be placed in a dry well ventilated place away fr...

Страница 10: ...P10...

Страница 11: ...llowed either u Liquified petroleum gas pot must be with qualified pressure reducing valve rated pressure 2800KPA the distance between roaster and gas pot shouldn t less than 100cm and the advisable h...

Страница 12: ...P12...

Страница 13: ...Equipment structure P13 LED Lamp Hopper Hopper Valve Electrical Control Box Vewing Window Front Bearing Adjust Claff Collector Cyclone Bean Release Lever Cooling Tray Discharged Bean Switch Sample Spo...

Страница 14: ...st speed meter Exhaust speed controller Drum speed control meter Power Roasting time Drum Switch Air Tempe Timer Cooling fan switch Drum Speed controller Cooling Switch Exhast switch Timer setting Tim...

Страница 15: ...ture reduce 10c the machine will supply the gas and fire automatically Pressing shift key down key and up key can set the temperature NOTE In genera please do not use the Mode Key due to the machine h...

Страница 16: ...P16 Gas Power adjustment guidance u Gas Pressure Adjustment Knob To left turn down pressure heating power low To right turn up pressure heating power strong...

Страница 17: ...request on roasting then no need to do these steps before every starting on 3 Turn on the operation switch Turn on the start switch to preheating NOTE Start switch Can Not be turn on if the operation...

Страница 18: ...duce the speed of rise temperature making the beans finish the second crack completely Then open the cooling air flow make sure it is fully open adjust the exhaust air flow at 1 scale turn on the cool...

Страница 19: ...oling tray there will collect some coffee beans residue or it will influence the cooling system Besides that the conveyer belt and cooling motor also should be clean and adjusted d If the machine work...

Страница 20: ...you add the grease please make sure you have turned off the power and the machine is under the room temperature do this operation to avoid harm b Loose three screws of the front pedestal cap by Allen...

Страница 21: ...front bearing bearing seat can adjust the space between drum and the front front panel Loose the 3 three screws In the picture turn left the space will be smaller turn right the space will bigger when...

Страница 22: ...llector cyclone if they are blocked sparks and yellow smoke leak out Checking exhaust motor and exhaust pipe if there are chaff in it CAN NOT ignition Checking the Gas cylinder valves if it is unscrew...