Biddle CASSETTAIR CEILING HEATER Скачать руководство пользователя страница 1

 

January 2013 

 

Page 1 of 15 

 

 

   

 

 

 

 CASSETTAIR CEILING HEATER 

 

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

 

    
 
 
 
 
 

      
 
 
 
 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION 

 

Biddle Air Systems Ltd 

St. Mary’s Road  Nuneaton 

Warwickshire  England 

CV11 5AU 

 

Email: [email protected] 

Tel:  +44 (0) 24 76 384233 
Fax: +44 (0) 24 76 373621 

www.biddle-air.co.uk

 

 
 
 

 

Содержание CASSETTAIR CEILING HEATER

Страница 1: ...ION MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Biddle Air Systems Ltd St Mary s Road Nuneaton Warwickshire England CV11 5AU Email sales biddle air...

Страница 2: ...packaging for correct delivery Make sure that all components and accompanying parts have been supplied Immediately report to the supplier if anything is missing or damaged For your records Date of Pur...

Страница 3: ...tributed through the outlet grille Ceiling Suspension Cassettair can be mounted either before or after the ceiling suspended grid system is installed The ceiling heater has been designed to easily fit...

Страница 4: ...the installer to ensure that the building fixing points and suspension system used are suitable for the ceiling cassette heater being installed 22mm LPHW Connections Suitable water mains isolation val...

Страница 5: ...January 2013 Page 5 of 15 Figure 1 Cassettair KLV1 KLV1 CB 620 570 570 280 740 840 Controls Electrical Connection Valve Cable Entry Point Water Return Water Flow 620 610 260 180...

Страница 6: ...sh one spring loaded hinge as indicated on the insert and locate hinge pin into the appropriate mount bracket Repeat with other spring loaded hinge and affix grille to cassette heater Once the above i...

Страница 7: ...ssible position The cassette heater must be earthed Ensure that the supply cables circuit breakers and other electrical installation equipment are correctly sized for the cassette heater being install...

Страница 8: ...in the back casing Fix the back casing to the wall and fasten the cable leaving 9cm protruding If required set the DIP switches in the front casing refer to pages 9 and 12 Plug the control cable into...

Страница 9: ...DIP2 ON Thermostat Master Only the air sensor thermistor in the master cassette heater will be used for measuring the reference air temperature for the whole master slave installation DIP3 Option The...

Страница 10: ...l fitted on the ECONTROL board for BMS remote On Off feature If the terminal is linked i e by 2 wires to a remote volt free contact the unit will run If it is open circuit across the terminal the unit...

Страница 11: ...January 2013 Page 11 of 15 Wiring Diagram...

Страница 12: ...ater off with all the LED s switched off If a heater is heating when switched off the fan will DIP Switch Settings At the back of the PCB there are four DIP switches see above that provide the followi...

Страница 13: ...that they understand how it operates Explain also the service intervals and that the unit must be regularly cleaned Fault Conditions Cassettair ceiling heaters are fitted with two internal electrical...

Страница 14: ...nd push On Off switch to turn unit on Select heat output Contact Installer Contact Installer Contact Installer No Is Electrical Power switched on Are the fans operating correctly Is the unit dischargi...

Страница 15: ...f dirt and debris within the ceiling cassette heater please note that the motor s are permanently lubricated and require no additional lubrication Once the ceiling cassette heater has been cleaned che...