background image

E N G L I S H

User Manual

BI Communications

Innovation through Technology

ProST

Structured Cable Tester

& TDR Fault Locator

Structured Cable Tester

& TDR Fault Locator

Pro

BI Communications

Innovation through Technology

18:24

LanCaster

Pro ST

03:11:05

TIA568

STP Vp=79%

Содержание Lan Caster ProST

Страница 1: ...tions Innovation through Technology Pro ProST ST Structured Cable Tester TDR Fault Locator Structured Cable Tester TDR Fault Locator Pro Pro BI Communications Innovation through Technology 18 24 LanCa...

Страница 2: ......

Страница 3: ...Set Time And Date 13 4 6 Select Wiring Type 13 4 7 Set Volocity Of Propogation 13 4 8 Adjusting Contrast 14 4 9 Setting Auto Shutdown 14 4 10 Address Settings 14 4 11 Volocity Of Propogation 15 5 1 T...

Страница 4: ...ECTION 6 DOWNLOADING TO P C SECTION 7 WIRING PROTOCOLS SECTION 8 MAINTENANCE 6 1 Linking Lancaster Pro ST To PC 25 6 2 Selective Download 25 6 3 Full Download 25 6 4 Erasing Memory 26 TABLE OF CONTENT...

Страница 5: ...rical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation Use only specified replacement parts when servicing the instrument This symbol on the instrument...

Страница 6: ...e that the contents are consistent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your d...

Страница 7: ...e main unit with a red green pass fail LED on the remote unit When plugged into an active port it will emit an audible tone if telephone voltages are present on any of the pins and will identify 10 ba...

Страница 8: ...he following functions when menu is selected 5 To scroll cursor arrow 3 To increment setting 4 To decrement setting 6 Return to menu 8 Structured Cable Tester TDR Fault Locator Structured Cable Tester...

Страница 9: ...etwork Voltage presence Test Inhibit Inhibits T esting in the presence of live voltages Tone Generator T one generator oscillating 810Hz 1110Hz Battery indicator Gas Gauge Bargraph Main Unit Display 1...

Страница 10: ...2 to 112 F 0 to 40 C 5 to 95 RH non condensing Main Unit Weight 12 oz 350g Main Unit Dimensions 6 5 x 3 5 x 1 5 165 x 90 x 37mm Remote Weight 1 5 oz 40g Remote Dimensions 2 5 x 2 0 x 1 0 65 x 52 x 25m...

Страница 11: ...s stored max 1 000 The following parameters will need to be set prior to use refer to 4 2 for menu locations 1 2 The Lancaster Pro ST time and date is set at G M T Grenwich Mean Time Prior to use the...

Страница 12: ...24 you are about to erase the memory do you want to continue No yes 03 11 05 18 24 LanCaster PRO ST 03 11 05 TIA568 STP Vp 79 000 18 24 00000 selective download full download 03 11 05 18 24 address s...

Страница 13: ...t Time and Date Menu Level 4 Press to move to desired position Press and to incremen or decrement When time and date are set correctly press to return to menu 4 6 Set Wiring Type Menu Level 2 Press to...

Страница 14: ...mbination of alpha A Z or numeric 0 9 allowing identification of customer building floor number or cabinet etc The last four characters are numeric only 0 9 for port identification and will automatica...

Страница 15: ...may list the Vp on their specification sheet or may be able to provide it when asked Sometimes this value is not readily available or the user may wish to determine it specifically to compensate for e...

Страница 16: ...ing and display the following Telephone Voltage detected on Pin X NOTE The pin on the RJ45 connection on which the voltage is detected is displayed In the event of a TNV Telecom Network Voltage Warnin...

Страница 17: ...it to the other end of the same cable Press the button 5 2 Service Detection 17 T oken Ring 10base T 100Mbit No Service Unknown Service 5 3 General Operation Structured Cable Tester TDR Fault Locator...

Страница 18: ...e display will briefly show the following message while testing is being performed Test in Progress This screen is quickly followed by the test results screen T est Pass OK Screen T est Failed Screen...

Страница 19: ...d by a double beep from the main unit and a double green flash on the LED of the active remote unit Next information about the test type selected along with a mea sured value of the cable length and a...

Страница 20: ...nit will show the fault as at the near end or the remote end These faults are the most common and are mainly due to termination problems If the fault occurs some way along the cable or link under test...

Страница 21: ...following is displayed Split Pair ID1 FAILED TIA568 L 94ft Vp 71 4 5 1 2 3 6 7 8 S Split Pair Pin 1 2 3 6 4 5 1 2 3 6 7 8 S NOTE For cables less than 6 ft 2m in length the tester is unable to disting...

Страница 22: ...y Shorts Reversals Opens For example on a cable with an Open on pin 3 and a Short between pins 7 and 8 only the Short in pins 7 and 8 will be reported If a wire map test is performed without a remote...

Страница 23: ...is a fault on the pair which is preventing the TDR circuit from measuring the length Length will be displayed in the selected units either meters or feet and the Vp and cable testing standard will als...

Страница 24: ...be used as a tone generator to trace and identify cables and wires The user will need a cable tone tracer To selectTone Generator Menu level 2 Press to move to Warble Tone press to select The warble...

Страница 25: ...2 Selective Download 18 24 000000 Selective Download Full Download 03 11 05 18 24 y336f Selective Download Full Download 03 11 05 Press to move cursor and buttons will increment and decrement digits...

Страница 26: ...press to return to menu 18 24 you are about to erase the memory do you want to continue No yes 03 11 05 WHEN THIS FUNCTION HAS BEEN COMPLETED ALL STORED TEST RESULTS WILL BE DELETED ENSURE RESULTS HA...

Страница 27: ...one or two wires in the same pair One or more pairs may also be opened in the same cable 4 5 3 6 1 2 7 8 4 5 3 6 1 2 7 8 Pair 1 Pair 2 Pair 3 Pair 4 SHORTED PAIR SH One specific pair is shorted 4 5 3...

Страница 28: ...o or more wires and pairs may be affected in the same cable 4 5 3 6 1 2 7 8 4 5 3 6 1 2 7 8 Pair 1 Pair 2 Pair 3 Pair 4 CROSSED WIRES CW Two wires from different pairs are crossed at one end Two or mo...

Страница 29: ...5 3 6 1 2 7 8 Pair 1 Pair 2 Pair 3 Pair 4 SPLIT PAIRS SP One pair uses one wire from another pair The cable will work but cross talk may occur Two or more pairs in the same cable may be split 1 2 7 8...

Страница 30: ...th lightly dampened with soapy water Rinse with a damp cloth and then dry with a dry cloth Do not splash water directly on the instrument Do not use alcohol solvents or hydrocarbons 8 3 Storage If the...