background image

NEIS-RM Intercom  Operating Manual

NEIS-RM Intercom  Operating Manual

Page 10

 3. Installation

3.

Installation.

3.1

Basic installation diagram.

Desk console

Power supply

Quiet area

Noisy area

Remote

Microphone

Loudspeaker

CAT5 cable

Figure 2. Basic block diagram.

Figure 3. Power supply.

Push pins onto

power supply body

3.2 Power supply.

The medical power supply used for the 

NEIS 

is a modular unit, and

consists of a modular pin unit and the power supply so as to
accommodate the different types of voltage and connections around
the world.  Before the power supply can be used, plug the pin unit
supplied onto the power supply body until it clicks into place.

Page 11

3.3

Loudspeaker mounting.

Figure 4. Loudspeaker connections.

Rear of speaker unit

Close up of

connections and

controls

Volume

control

Microphone

connector

CAT5 cable

connection

Microphone
assembly -
25ft

3.

Installation.

Mount the wall bracket supplied with the speaker unit in a suitable
location in the noisy area, so that it optimizes the audio for the user.
The microphone and cat 5 cable should be connected at the rear of
the speaker before the speaker is secured into the bracket, and the
microphone should be mounted at least 1 metre away from the
speaker.

Содержание NEIS-RM

Страница 1: ......

Страница 2: ...written consent of bhi Ltd Disclaimer The information in this document is subject to change without notice bhi Ltd makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Furthermore bhi Ltd reserves the right to revise this publication and to make changes from time to time...

Страница 3: ...S DU Desk console NEIS SPKR Loudspeaker unit Note We recommend that installation be carried out by qualified personnel Please study this manual before attempting to install the intercom To install this intercom you will need the following additional items CAT5 network cable connections straight through Suitable fixings for mounting the loudspeaker Suitable tools for installation of the above Page ...

Страница 4: ......

Страница 5: ......

Страница 6: ...o way voice communications are important including Hospital radiotherapy radiology treatment rooms mines railway and transport depots customer help points factories office communications In fact the NEIS provides a simple effective solution for anyone trying to communicate from within a noisy environment Simply plug in the power and the system is ready to go The NEIS consists of a stylish robust d...

Страница 7: ...4 Operation 4 Operation 4 1 Desk console controls Figure 7 Rear view of desk unit Power on off volume control Noise cancellation on off switch CAT 5 Loudspeaker connector Power connector Power On Off Ensure the power supply is plugged in at the wall socket and the wall socket is turned on Using the on off Volume control knob on the rear of the desk unit turn on the unit Noise Cancellation The desk...

Страница 8: ......

Страница 9: ... NEIS MIC holder Contact bhi for more information 2 2 1Loudspeaker unit The loudspeaker unit mounts in a suitable location in the noisy area to give optimum voice quality to the user The unit features a separate volume control enabling the speaker output volume to be set up to suit the surrounding conditions and environment The cat 5 cable connects at the rear of the unit 2 2 2 Remote microphone T...

Страница 10: ...nections around the world Before the power supply can be used plug the pin unit supplied onto the power supply body until it clicks into place Page 11 3 3 Loudspeaker mounting Figure 4 Loudspeaker connections Rear of speaker unit Close up of connections and controls Volume control Microphone connector CAT5 cable connection Microphone assembly 25ft 3 Installation Mount the wall bracket supplied wit...

Отзывы: