possible injury from flying debris during the hammer operation.
2) In normal operation, the critical cases - the critical noise level of 90 dB(A) is reached or
exceeded, the machine operator and any other workers in the noise area must wear
personal noise protection gear.
3) The hydraulic hammer should be operated only from the driver's seat and should not be
put into operation until both carrier and hammer are in the correct position.
4) Shut off the hydraulic hammer immediately if anyone moves in the danger area, which
is much larger for hammer operation than for carrier operation due to the risk of flying
debris.
5) When working with a hydraulic hammer, operation of the carrier is governed by carrier
manufacturer's safety regulations.
6) The hydraulic hammer is only suitable for the applications described. Never pry with
the tools.
7) Check the oil temperature constantly to ensure it does not exceed 80℃. If higher
temperatures are measured in the tank, an oil cooler must be fitted.
8) Flying debris from the hammer, tool, rock or other material may cause serious or fatal
injury to the operator, personal protection equipment must be used.
9) When operating the hammer, ear, eye and breast protection appliance must be used at
all time.
10) Do not operate the hammer in the underwater and mud without proper equipment.
11) Stop the engine before attempting to make any repairs, adjustment or servicing to
either the carrier or the hammer.
12) Do not operate the carrier if you are under the influence of drugs or alcohol.
13) Remove hammer from carrier before the transport.
14) Before leaving the carrier, always lower the boom and insure the carrier is stable.
15) Never leave the carrier with the engine running.
Danger of Explosion
․
N₂ gas cylinder should be used for charging gas into the accumulator and head cap.
․
Release all pressure prior to servicing or disassembly.
. Do not open without reading the Manual or consulting the authorized service man!
Unauthorized repair work on the accumulator is forbidden. Defective accumulators must be
replaced.
․
All accumulators are subjected to recurring tests by experts, at the latest after 5 years.
All hydraulic oil brands used in the carrier units are suitable for operating. The use of
other hydraulic fluids is only permissible after consulting with our service station. In summer
and in regions with high temperatures, it is recommended that oils with a viscosity of
category H-LP 36 or higher be used. At temperature lower than -20℃(4°F), the hydraulic
Содержание HydroRam HK300S
Страница 1: ...BHI HydroRam Hydraulic Hammer HK300S Operation Manual Parts List ...
Страница 6: ...BHI Best Hammer Industries 3 ...
Страница 17: ...BHI Best Hammer Industries 14 3 External Dimension Power cell and Silence Bracket ...
Страница 41: ...BHI Best Hammer Industries 38 Ⅸ AUTO LUBE KIT OPTION ...
Страница 44: ...BHI BHI HydroRam Hydraulic Hammer HK300S Parts List ...
Страница 45: ...BHI Best Hammer Industries 2 HK300S POWER CELL PARTS LIST ...
Страница 50: ...BHI Best Hammer Industries 7 HK300S BRACKET PARTS LIST ...