INSTALLATION MANUAL
Terminal
Definition
Description
Limit
swit
ch
for
LUX
B
T
LUX
G
B
T
41
+ REF SWE
Limit switch common
42
SW 1
Limit switch control motor 1.
43
SW 2
Limit switch control motor 2.
A
cc
essories
po
w
er
supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
Commands
60
Common
IC 1 and IC 2 inputs common
61
IC 1
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
62
IC 2
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
63
Common
IC 3 and IC 4 inputs common
64
IC 3
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
65
IC 4
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Saf
et
y
de
vic
es
70
Common
STOP, SAFE 1 and SAFE 2 inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
SAFE 1
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
73
FAULT 1
Test input for safety devices connected to SAFE 1.
74
SAFE 2
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
75
FAULT 2
Test input for safety devices connected to SAFE 2.
76
Common
SAFE 3 and SAFE 4 inputs common
77
SAFE 3
Configurable safety input 3 (N.C.) - Default PHOT OP.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
78
FAULT 3
Test input for safety devices connected to SAFE 3.
79
SAFE 4
Configurable safety input 4 (N.C.) - Default PHOT CL.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
80
FAULT 4
Test input for safety devices connected to SAFE 4.
81
Common
SAFE 5 and SAFE 6 inputs common
82
SAFE 5
Configurable safety input 5 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
83
FAULT 5
Test input for safety devices connected to SAFE 5.
84
SAFE 6
Configurable safety input 6 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
85
FAULT 6
Test input for safety devices connected to SAFE 6.
A
nt
enna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can
interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
#
SHIELD
AUX output configuration
Aux logic= 0 - 2ND RADIO CHANNEL output.
Contact stays closed for 1s when 2nd radio channel is activated.
Aux logic= 1 - SCA gATE OPEN LIgHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIgHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIgHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIgHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - gATE OPEN ALARM output.
Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHINg LIgHT output.
Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output.
Contact stays closed for 2 seconds each time gate is opened.
Aux logic= 8 - MAgNETIC LOCK output.
Contact stays closed while gate is closed.
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to
STEP-BY-STEP MOV
. logic. External start for traffic light control.