INSTALLER WARNINGS

Anything that is not explicitly provided for in the installation ma-

nual is not allowed. The operator’s proper operation can only be 

guaranteed if the information given is complied with. The Firm shall 

not be answerable for damage caused by failure to comply with the 

instructions featured herein.

While we will not alter the product’s essential features, the Firm re-

serves the right, at any time, to make those changes deemed oppor-

tune to improve the product from a technical, design or commercial 

point of view, and will not be required to update this publication 

accordingly.

WARNING! Important safety instructions. Carefully read and comply with 

all the warnings and instructions that come with the product as incorrect 

installation can cause injury to people and animals and damage to property. 

The warnings and instructions give important information regarding safety, 

installation, use and maintenance. Keep hold of instructions so that you can 

attach them to the technical file and keep them handy for future reference.

GENERAL SAFETY

This product has been designed and built solely for the purpose indicated herein. 

Uses other than those indicated herein might cause damage to the product and 

create a hazard.

- The units making up the machine and its installation must meet the requirements 

of the following European Directives, where applicable: 2004/108/EC, 2006/95/

EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries 

outside the EEC, it is advisable to comply with the standards mentioned, in ad-

dition to any national standards in force, to achieve a good level of safety.

- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims 

all responsibility resulting from improper use or any use other than that for 

which the product has been designed, as indicated herein, as well as for failure 

to apply Good Practice in the construction of entry systems (doors, gates, etc.) 

and for deformation that could occur during use.

- Before installing the product, make all structural changes required to produce 

safety gaps and to provide protection from or isolate all crushing, shearing and 

dragging hazard areas and danger zones in general in accordance with the 

provisions of standards EN 12604 and 12453 or any local installation standards. 

Check that the existing structure meets the necessary strength and stability 

requirements.

- Before commencing installation, check the product for damage.

- The Firm is not responsible for failure to apply Good Practice in the construction 

and maintenance of the doors, gates, etc. to be motorized, or for deformation 

that might occur during use. 

- Make sure the stated temperature range is compatible with the site in which the 

automated system is due to be installed.

- Do not install this product in an explosive atmosphere: the presence of flammable 

fumes or gas constitutes a serious safety hazard.

- Disconnect the electricity supply before performing any work on the system. 

Also disconnect buffer batteries, if any are connected.

- Before connecting the power supply, make sure the product’s ratings match the 

mains ratings and that a suitable residual current circuit breaker and overcurrent 

protection device have been installed upline from the electrical system. Have 

the automated system’s mains power supply fitted with a switch or omnipolar 

thermal-magnetic circuit breaker with a contact separation that meets code 

requirements.

- Make sure that upline from the mains power supply there is a residual current 

circuit breaker that trips at no more than 0.03A as well as any other equipment 

required by code.

- Make sure the earth system has been installed correctly: earth all the metal parts 

belonging to the entry system (doors, gates, etc.) and all parts of the system 

featuring an earth terminal.

- Installation must be carried out using safety devices and controls that meet 

standards EN 12978 and EN 12453.

- Impact forces can be reduced by using deformable edges.

- In the event impact forces exceed the values laid down by the relevant standards, 

apply electro-sensitive or pressure-sensitive devices.

- Apply all safety devices (photocells, safety edges, etc.) required to keep the 

area free of impact, crushing, dragging and shearing hazards. Bear in mind the 

standards and directives in force, Good Practice criteria, intended use, the instal-

lation environment, the operating logic of the system and forces generated by 

the automated system.

- Apply all signs required by current code to identify hazardous areas (residual 

risks). All installations must be visibly identified in compliance with the provisions 

of standard EN 13241-1.

Once installation is complete, apply a nameplate featuring the door/gate’s data.

- This product cannot be installed on leaves incorporating doors (unless the motor 

can be activated only when the door is closed).

- If the automated system is installed at a height of less than 2.5 m or is accessible, 

the electrical and mechanical parts must be suitably protected.

- Install any fixed controls in a position where they will not cause a hazard, away 

from moving parts. More specifically, hold-to-run controls must be positioned 

within direct sight of the part being controlled and, unless they are key operated, 

must be installed at a height of at least 1.5 m and in a place where they cannot 

be reached by the public.

- Apply at least one warning light (flashing light) in a visible position, and also 

attach a Warning sign to the structure. 

- Attach a label near the operating device, in a permanent fashion, with informa-

tion on how to operate the automated system’s manual release.

- Make sure that, during operation, mechanical risks are avoided or relevant 

protective measures taken and, more specifically, that nothing can be banged, 

crushed, caught or cut between the part being operated and surrounding parts.

- Once installation is complete, make sure the motor automation settings are 

correct and that the safety and release systems are working properly.

- Only use original spare parts for any maintenance or repair work. The Firm dis-

claims all responsibility for the correct operation and safety of the automated 

system if parts from other manufacturers are used.

- Do not make any modifications to the automated system’s components unless 

explicitly authorized by the Firm.

- Instruct the system’s user on what residual risks may be encountered, on the 

control systems that have been applied and on how to open the system manu-

ally in an emergency. give the user guide to the end user.

- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accord-

ance with the provisions of the laws in force. Keep nylon bags and polystyrene 

out of reach of children.

WIRING

WARNING! For connection to the mains power supply, use: a multicore cable with 

a cross-sectional area of at least 5x1.5mm

2

 or 4x1.5mm

2

 when dealing with three-

phase power supplies or 3x1.5mm

2

 for single-phase supplies (by way of example, 

type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm

2

). To con-

nect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm

2

.

-  Only use pushbuttons with a capacity of 10A-250V or more.

-  Wires must be secured with additional fastening near the terminals (for example, 

using cable clamps) in order to keep live parts well separated from safety extra 

low voltage parts.

-  During installation, the power cable must be stripped to allow the earth wire 

to be connected to the relevant terminal, while leaving the live wires as short 

as possible.  The earth wire must be the last to be pulled taut in the event the 

cable’s fastening device comes loose.

WARNING! safety extra low voltage wires must be kept physically separate from 

low voltage wires.

Only qualified personnel (professional installer) should be allowed to access 

live parts.

CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE

Before the automated system is finally put into operation, and during maintenance 

work, perform the following checks meticulously:

- Make sure all components are fastened securely.

- Check starting and stopping operations in the case of manual control.

- Check the logic for normal or personalized operation.

- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm 

of play along the full length of the rack; keep the track the gate slides on clean 

and free of debris at all times.

For sliding gates and doors only: make sure the gate’s running track is straight 

and horizontal and that the wheels are strong enough to take the weight of the 

gate.

For cantilever sliding gates only: make sure there is no dipping or swinging 

during operation.

For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.

- Check that all safety devices (photocells, safety edges, etc.) are working properly 

and that the anti-crush safety device is set correctly, making sure that the force 

of impact measured at the points provided for by standard EN 12445 is lower 

than the value laid down by standard EN 12453.

- Impact forces can be reduced by using deformable edges.

- Make sure that the emergency operation works, where this feature is provided.

- Check opening and closing operations with the control devices applied.

- Check that electrical connections and cabling are intact, making extra sure that 

insulating sheaths and cable glands are undamaged.

- While performing maintenance, clean the photocells’ optics.

- When the automated system is out of service for any length of time, activate the 

emergency release (see “EMERGENCY OPERATION” section) so that the operated 

part is made idle, thus allowing the gate to be opened and closed manually.

- If the power cord is damaged, it must be replaced by the manufacturer or their 

technical assistance department or other such qualified person to avoid any risk .

- If “D” type devices are installed (as defined by EN12453), connect in unverified 

mode, foresee mandatory maintenance at least every six months

WARNING! 

Remember that the drive is designed to make the gate/door easier to use and 

will not solve problems as a result of defective or poorly performed installation 

or lack of maintenance

SCRAPPING

Materials must be disposed of in accordance with the regulations in force. There 

are no particular hazards or risks involved in scrapping the automated system. For 

the purpose of recycling, it is best to separate dismantled parts into like materials 

(electrical parts - copper - aluminium - plastic - etc.).

DISMANTLING

If the automated system is being dismantled in order to be reassembled at another 

site, you are required to:

- Cut off the power and disconnect the whole electrical system.

- Remove the actuator from the base it is mounted on.

- Remove all the installation’s components.

- See to the replacement of any components that cannot be removed or happen 

to be damaged.

AVVERTENZE PER L’INSTALLATORE D811766_06

30  -

  THALIA P

D811780

 00100_06

Содержание THALIA P

Страница 1: ...tion Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen aan de binnenkant zorgvuldig QUADRO COMANDO CONTROL PANEL CENTRALE DE COMMANDE SELBSTÜBERWACHENDE STEUERUNG CUADRO DE MANDOS Bedie...

Страница 2: ...1 ENC1A SWO 1 SW 2 ENC1B SWC2 ENC2A SWO2 ENC2B 24V 24V 24 VSafe COM IC 1 IC 2 NO NO COM IC 3 IC 4 NO NO Ingressi finecorsa encoder Encoder limit switch inputs Entrées des fins de course encodeur Eingänge Anschlag Encoder Entradas finales de carrera Encoder ingangen Alimentazione accessori Accessories power supply Alimentation des accessoires Stromversorgung Zubehör Alimentación accesorios Voeding ...

Страница 3: ... M2 M1 M1 M2 M1 M2 M2 M1 M2 M1 inv direz ap open in other direct inv sens ouv inv richt offnung inv direcc ap Omkering openingsrichting 1 ext inv direz ap open in other direct inv sens ouv inv richt offnung inv direcc ap Omkering openingsrichting 1 ext inv direz ap open in other direct inv sens ouv inv richt offnung inv direcc ap Omkering openingsrichting 1 ext inv direz ap open in other direct in...

Страница 4: ... M1 M2 M2 M1 M2 M1 Bianco Bianco Rosso Nero White Red Black Blanc Rouge Noir Weiß Rot Nero Blanco Rojo Negro Wit Rood Zwart Rosso Rosso Bianco Bianco Nero Nero Rosso Nero inv direz ap open in other direct inv sens ouv inv richt offnung inv direcc ap Omkering openingsrichting 1 ext inv direz ap open in other direct inv sens ouv inv richt offnung inv direcc ap Omkering openingsrichting 1 ext inv dir...

Страница 5: ...le sr funzionamento semi aut residenziale ac funzionamento automatico condominiale Sc funzionamento semi automatico condominiale Ind funzionamento a uomo presente AR preset sr ac sc ind regolazione finecorsa di apertura motore 1 regolazione finecorsa di apertura motore 2 regolazione finecorsa di chiusura motore 2 regolazione finecorsa di chiusura motore 1 opm1 opm2 clm2 clm1 ersu fine o o reg fc 2...

Страница 6: ...utomatica 0 1 0 1 0 0 Chiusura rapida 0 0 0 0 0 0 Movimento passo passo 0 1 0 1 0 0 Preallarme 0 0 0 1 1 0 Uomo presente 0 0 0 0 0 1 Blocca impulsi in apertura 0 0 0 1 1 0 Blocca impulsi in TCA 0 0 0 0 0 0 Blocca impulsi in chiusura 0 0 0 0 0 0 Colpo di ariete in apertura 0 0 0 0 0 0 Colpo di ariete in chiusura 0 0 0 0 0 0 Mantenimento blocco 0 0 0 0 0 0 Pressione finecorsa chiusura 0 0 0 0 0 0 IC...

Страница 7: ...own motor 1 opening limit switch adjustment motor 2 opening limit switch adjustment motor 2 closing limit switch adjustment motor 1 closing limit switch adjustment ar automatic operation residential sr semiautomatic operation residential ac automatic operation commercial Sc semiautomatic operation commercial Ind dead man operation opm1 opm2 clm2 clm1 ersu end o o 2 1 2 1 2 1 2 1 LUX BT LUX G BT EL...

Страница 8: ... 0 1 0 1 0 0 Fast closing 0 0 0 0 0 0 Step by step movement 0 1 0 1 0 0 Pre alarm 0 0 0 1 1 0 Deadman 0 0 0 0 0 1 Block pulses during opening 0 0 0 1 1 0 Block pulses during TCA 0 0 0 0 0 0 Block pulses during closing 0 0 0 0 0 0 Hammer during opening 0 0 0 0 0 0 Hammer during closing 0 0 0 0 0 0 Stop maintenance 0 0 0 0 0 0 Closing limit switch pressure 0 0 0 0 0 0 ICE feature 0 0 0 0 0 0 1 motor...

Страница 9: ...atique collectif Sc fonctionnementsemi automatique collectif Ind fonctionnement à homme présent x1 MIN 1 MAX 3 AUTO OPEN AUTO CLOSE Monter Descendre Confirmation allumage afficheur Sortir du menu AR preset sr ac sc ind opm1 opm2 clm2 clm1 ersu fin o o 2 1 2 1 2 1 2 1 LUX BT LUX G BT ELI BT PHOBOS BT IGEA BT SUB BT regL fc réglage fin de course d ouverture moteur 1 réglage fin de course d ouverture...

Страница 10: ...utomatique 0 1 0 1 0 0 Fermeture rapide 0 0 0 0 0 0 Mouvement pas à pas 0 1 0 1 0 0 Préalarme 0 0 0 1 1 0 Homme présent 0 0 0 0 0 1 Verrouillage impulsions à l ouverture 0 0 0 1 1 0 Verrouillage impulsions en TCA 0 0 0 0 0 0 Verrouillage impulsions à la fermeture 0 0 0 0 0 0 Coup de bélier à l ouverture 0 0 0 0 0 0 Coup de bélier à la fermeture 0 0 0 0 0 0 Maintien verrouillage 0 0 0 0 0 0 Pressio...

Страница 11: ...ikbetrieb Hausbereich Sc Halbautomatikbetrieb Hausbereich Ind Halbautomatikbetrieb Hausbereich Öffnung nach innen EXT Öffnung nach außen type eli phob igea 2 n mot 1 x1 autoset O 01 gevue taste verst taste loslassen speichern hs ende o o MIN 1 MAX 3 AUTO OPEN AUTO CLOSE Aufwärts Abwärts Bestätigung Aufleuchten Display Zurück zum Hauptmenü AR preset sr ac sc ind opm1 opm2 clm2 clm1 ersu ende o o en...

Страница 12: ...ische Schließung 0 1 0 1 0 0 Schnelle Schließung 0 0 0 0 0 0 Bewegung Schritt Schritt 0 1 0 1 0 0 Voralarm 0 0 0 1 1 0 Mann anwesend 0 0 0 0 0 1 Blockiert Öffnungsimpulse 0 0 0 1 1 0 Blockiert TCA Impulse 0 0 0 0 0 0 Blockieren Impulse Schließen 0 0 0 0 0 0 Widderschlag Öffnung 0 0 0 0 0 0 Widderschlag Schließung 0 0 0 0 0 0 Halten Blockierung 0 0 0 0 0 0 Drücken Endschalter Schließung 0 0 0 0 0 0...

Страница 13: ...to automático en edificios Sc funcionamiento semi aut en edificios Ind funcionamiento con hombre presente apertura hacia dentro EXT apertura hacia afuera TIPO eli phob igea 2 autoset O 01 tecla deseada anad start suelte RADIOM FIN o o n mot 1 x1 MIN 1 MAX 3 AUTO OPEN AUTO CLOSE Desplazar hacia arriba Desplazar hacia abajo Confirmación Encendido pantalla Retorno al menú principal LEYENDA AR preset ...

Страница 14: ...re Automático 0 1 0 1 0 0 Cierre rápido 0 0 0 0 0 0 Movimiento paso a paso 0 1 0 1 0 0 Prealarma 0 0 0 1 1 0 Hombre presente 0 0 0 0 0 1 Bloqueo impulsos en fase de apertura 0 0 0 1 1 0 Bloqueo impulsos en TCA 0 0 0 0 0 0 Bloquea impulsos en fase de cierre 0 0 0 0 0 0 Golpe de ariete en fase de apertura 0 0 0 0 0 0 Golpe de ariete en fase de cierre 0 0 0 0 0 0 Mantenimiento bloqueo 0 0 0 0 0 0 Pre...

Страница 15: ...chappelijk semi automatische werking gemeenschappelijk werking bij aanwezige persoon opening naar binnen EXT opening naar buiten type eli phob igea 2 autoset O 01 desidered button hidden button release mem remotes end o o n mot 1 x1 ar sr ac Sc Ind AR preset sr ac sc ind opm1 opm2 clm2 clm1 ersu end o o l sw adj 2 1 2 1 2 1 2 1 LUX BT LUX G BT ELI BT PHOBOS BT IGEA BT SUB BT MIN 1 MAX 3 AUTO OPEN ...

Страница 16: ...matische Sluiting 0 1 0 1 0 0 Snelle sluiting 0 0 0 0 0 0 Stap voor stap beweging 0 1 0 1 0 0 Vooralarm 0 0 0 1 1 0 Persoon aanwezig 0 0 0 0 0 1 Blokkeert impulsen bij opening 0 0 0 1 1 0 Blokkeert impulsen in TCA 0 0 0 0 0 0 Blokkeert impulsen bij sluiting 0 0 0 0 0 0 Drukstoot bij opening 0 0 0 0 0 0 Drukstoot bij sluiting 0 0 0 0 0 0 Handhaving blokkering 0 0 0 0 0 0 Druk aanslag sluiting 0 0 0...

Страница 17: ...PHOT CL 1 BAR 1 BAR 2 BAR 50 52 50 52 50 51 50 51 50 51 50 51 50 76 77 76 77 78 76 76 77 78 51 51 50 51 50 51 50 52 52 52 77 76 77 76 78 77 76 51 50 76 78 1 2 1 2 3 4 5 51 TX1 RX1 Bar 1 1 2 3 4 5 6 1 2 1 2 3 4 5 52 50 TX1 RX1 1 2 1 2 3 4 5 TX1 RX1 1 2 1 2 3 4 5 TX2 RX2 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 1 2 1 2 3 4 5 TX1 RX1 Bar 1 1 2 3 4 5 6 1 2 1 2 3 4 5 TX1 RX1 1 2 1 2 3 4 5 ...

Страница 18: ...nec tions to motor Hardware problems with board contact technical assistance ER2x Encoder error Motor power or encoder sig nal cables inver ted disconnected Actuator movement is too slow or stopped with respect to programmed operation ER3x Reverse due to obstacle Amperostop Check for obstacles in path ER4x Thermal cutout Allow automated device to cool ER5x Communication error with remote devices C...

Страница 19: ...ached by the public Apply at least one warning light flashing light in a visible position and also attach a Warning sign to the structure Attach a label near the operating device in a permanent fashion with informa tion on how to operate the automated system s manual release Make sure that during operation mechanical risks are avoided or relevant protective measures taken and more specifically tha...

Страница 20: ...securedwithadditionalfasteningneartheterminals usingdevices such as cable clamps All connecting cables must be kept far enough away from the dissipater Terminal Definition Description Power supply L LINE Single phase power supply 220 230V 50 60Hz N NEUTRAL JP5 TRANSF PRIM Transformer primary winding connection 220 230V JP7 JP21 TRANSF SEC Board power supply 24V Transformer secondary winding 24V Bu...

Страница 21: ...devices connected to SAFE 3 79 SAFE 4 Configurable safety input 4 N C Default PHOT CL PHOT PHOT TEST PHOT OP PHOT OP TEST PHOT CL PHOT CL TEST BAR BAR TEST BAR 8K2 Refer to the Safety input configuration table 80 FAULT 4 Test input for safety devices connected to SAFE 4 81 Common SAFE 5 and SAFE 6 inputs common 82 SAFE 5 Configurable safety input 5 N C Default PHOT PHOT PHOT TEST PHOT OP PHOT OP T...

Страница 22: ...s code is required to subsequently clone the radio transmitters The Clonix built in on board receiver also has a number of important advanced features Cloning of master transmitter rolling code or fixed code Cloning to replace transmitters already entered in receiver Transmitter database management Receiver community management To use these advanced features refer to the universal handheld program...

Страница 23: ...e force stored during the autoset cycle and subsequently updated before an obstacle alarm is generated The parameter is set automatically by the autoset function WARNING It affects impact force directly make sure that current safety requirements are met with the set value Install anti crush safety devices where necessary CLS FORCE 1 99 50 Leaf force during closing Force exerted by leaf leaves duri...

Страница 24: ...s OPEN UP Input 62 is configured as CLOSE UP WARNING with the device set to Emergency Deadman mode safety devices are not enabled IBL OPEN Block pulses during opening 0 0 Pulse from inputs configured as Start E Start I Ped has effect during opening 1 Pulse from inputs configured as Start E Start I Ped has no effect during opening IBL TCA Block pulses during TCA 0 0 Pulse from inputs configured as ...

Страница 25: ...perating mode See Fig G Ref D SAFE 1 Configuration of safety input SAFE 1 72 0 0 Input configured as Phot photocell 1 Input configured as Phot test tested photocell 2 Input configured as Phot op photocell active during opening only 3 Input configured as Phot op test tested photocell active during opening only SAFE 2 Configuration of safety input SAFE 2 74 6 4 Input configured as Phot cl photocell ...

Страница 26: ...ontrol panel IMPORTANT Enables the automatic addition of new transmitters clones and replays SERIAL MODE Serial mode Identifies how board is configured in a BFT network connection 0 0 Standard SLAVE board receives and communicates commands diagnostics etc 1 Standard MASTER board sends activation commands START OPEN CLOSE PED STOP to other boards ADDRESS Address 0 ___ Identifies board address from ...

Страница 27: ...command 5 Input configured as Timer command 6 Input configured as Timer Pedestrian command 7 Input configured as Phot photocell safety 8 Input configured as Phot op safety photocell active during opening only 9 Input configured as Phot cl safety photocell active during closing only 10 Input configured as Bar safety safety edge EXPO1 Configuration of EXPO2 output on input output expansion board 4 5...

Отзывы: